Remote controller with weekly timer
Owner’s Manual
– 25 –
EN
• Display/non-display of clock <code
no.13>
This item selects and sets whether the day
of the week and clock time are to be
displayed.
Setting: 0000 (factory setting)
▼
Code No.13
O: Display
X: No display
• Selection of operation when power is
restored after a power outage <code
No.14>
This item selects the operation to be
performed when power is restored after a
power outage occurred during a
scheduled operation.
0000: No operations are performed when
the power is restored, and the scheduled
operation is resumed as soon as the
program time is reached after the power
has been restored. (When the power is
restored, the scheduled operation is
based on the operation of the indoor
units.)
0001: If there was a programmed
operation during the power outage, that
operation is performed when the program
is resumed. If there is no programmed
operation or if the “Continue xx” setting is
in place, the operation prior to the power
outage is resumed.
Selecting the functions using the DIP
switches of the remote controller
• The following functions can be selected
using the DIP switches on the remote
controller’s circuit board.
Setting procedure
• Open the back cover of the remote
controller, and select the functions using
the DIP switches located at the bottom left
of the circuit board.
• After establishing the settings, turn the
ground fault interrupter off and then back
on.
Setting items
• Remote controller header/follower setting:
Bit 1
When operating the air conditioner using
two remote controllers, set one of the
controls to be the follower.
* Set the remote controller used as the
schedule timer to be the header.
• Operation function setting: Bit 2
One of the following three operation
functions can be selected and set.
1.Scheduled operation function
2.Timer operation function
3.No scheduled or timer operation
function
Setting
Scheduled operation
underway
Scheduled operation in
standby
Air
conditioner
now
operating
Air
conditioner
now shut
down
Air
conditioner
now
operating
Air
conditioner
now shut
down
0000
O
O
O
O
0001
X
X
X
X
0002
O
O
X
X
0003
O
X
X
X
0004
O
O
O
X
0005
O
X
O
X
Bit 1
Bit 2
Bit 3
Bit 4
ON: Follower
ON: Timer
operation
—
—
OFF: No
function
OFF: Header
ON: Timer
operation
—
—
OFF:
Scheduled
operation
Bit
[DIP switches] (factory settings)
ON
OFF
24-EN