Bend the connecting pipe within a radius of 1-3/16 in. (30 mm).

To connect the pipe after the unit has been installed (

fi

 gure)

 

NOTE

If the pipe is bent incorrectly, the indoor unit may set on the wall unstably.
After passing the connecting pipe through the pipe hole, connect the 
connecting pipes to the refrigerant line and wrap facing tape around them.

CAUTION

•  Bind the refrigerant lines (two) and connecting cable with facing tape 

tightly. In case of leftward piping and rear-leftward piping, bind the 
refrigerant lines (two) only with facing tape.

Indoor unit

Connecting cable

Refrigerant lines

Installation plate

•  Carefully arrange pipes such that none of them stick out of the rear 

plate of the indoor unit.

•  Carefully connect the refrigerant lines and connecting pipes to one 

another and cut off the insulating tape wound on the connecting pipe 
to avoid double-taping at the joint; moreover, seal the joint with vinyl 
tape, etc.

•  Check for gas leaks before insulating. 

80

Liquid side

Gas side

(Forefront of 

fl

 are)

Outward form of indoor unit

R 1-3/16 in. (R 30 mm) (Use polisin 
(polyethylene) core or the like for bending 
pipe.)

Use the handle of a screwdriver, etc.

16-9/16 in.

(420 mm)

1-5/8 in.  (43 mm)

20-1/2 in.
(520 mm)

Indoor Unit Fixing

•  To detach the indoor unit from the 

mounting plate, pull the indoor unit toward 
you while pushing its bottom up as shown 
in the 

fi

 gure.

1

2

1

1.  Pass the pipe through the hole in the wall and hook the indoor unit on the 

upper hook of the installation plate.

2.  Swing the indoor unit to the right and left to con

fi

 rm that it is 

fi

 rmly hooked 

up to the mounting plate.

3.  While pressing the indoor unit onto the wall, hook it to the lower section 

of the mounting plate. Pull the indoor unit toward you to con

fi

 rm that it is 

fi

 rmly hooked up to mounting plate.

Hook here.

Installation plate

Hook

Press

(unhook)

Push

Push

Information

%

 

Screw

%

 

Screw

Due to piping installation, in some cases 
the lower section of the indoor unit may 
not completely attach to the mounting 
plate. In such a case, use the provided 
screws 

%

 to 

fi

 x the unit to the mounting 

plate.

Firmly insert the drain hose and drain cap; otherwise, water may leak.

In case of right or left piping

•  After making slits of the front panel with a 

knife or a making-off pin, cut them with a 
pair of nippers or an equivalent tool. 

In case of bottom right or bottom left piping

•  After making slits of the front panel with a 

knife or a making-off pin, cut them with a 
pair of nippers or an equivalent tool. 

Left-hand connection with piping

•  Bend the connecting pipe so that it is laid within 1-5/8 in. (43 mm) above 

the wall surface. If the connecting pipe is laid exceeding 1-5/8 in. (43 mm) 
above the wall surface, the indoor unit may set on the wall unstably.

  When bending the connecting pipe, make sure to use a spring bender to 

avoid crushing the pipe.

CAUTION

Slit

Slit

How to remove the drain cap

Clip the drain cap with needle-nose 
pliers and pull out.

How to 

fi

 x the drain cap

1)  Insert a hexagon wrench 

3/16 in. (4 mm) in the 
center head of the cap.

2)  Firmly insert the drain cap.

3/16 in.
(4 mm)

No gap

Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage from the plug.

Insert a hexagon
wrench 3/16 in. 
(4 mm).

How to remove the drain hose

•  The drain hose can be removed by removing the 

screw securing the drain hose and then pulling out 
the drain hose.

•  When removing the drain hose, be careful of any 

sharp edges the steel plate may have. Sharp 
edges can cause injuries.

•  To install the drain hose, insert the drain hose 

fi

 rmly until the connection part contacts the heat 

insulator, and then secure it with the original 
screws.

Heat insulator

Drain hose

1.  Die-cutting front panel slit

 

With a pair, of nippers, cut out the slit on the leftward or right side of the 
front panel for left or right connection, and the slit on the bottom left or right 
side of the front panel for bottom left or right connection.

2.  Changing drain hose

 

For leftward connection, bottom-leftward connection and rearleftward 
connection’s piping, it is necessary to change the drain hose and drain 
cap.

1110651824-1 EN.indd   10

1110651824-1 EN.indd   10

11/13/13   2:02 PM

11/13/13   2:02 PM

Содержание Carrier RAS-15

Страница 1: ...FRANÇAIS Indoor unit RAS 15 17 22EK Series Outdoor unit RAS 15 17 22EA Series AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL 1110651824 1 1110651824 1 EN indd 1 1110651824 1 EN indd 1 11 13 13 2 02 PM 11 13 13 2 02 PM ...

Страница 2: ...jo Eléctrico 7 UNIDAD INTERIOR 8 Situación de Instalación 8 Corte de un Orificio y Montaje de la Placa de Montaje 8 Conexión de Cables 9 Instalación la Tubería y el Tubo de Desagüe 9 Instalación de la Unidad Interior 10 Drenaje 11 Mando a distancia A B Selección 11 EVACUACIÓN 11 Evacuación 11 OTROS 12 Comprobación de Fugas 12 Prueba de Operación 12 Ajuste de Reinicio Automático 12 Troubleshooting ...

Страница 3: ... 4 6 35 Drain hose 19 11 16 0 5m Connecting pipe 15 5 16 0 39m Flare Ø1 2 12 70 For stud bold Ø2 1 4 6 8 15 32 215 5 Hanger Hanger Center line Installation plate outline Grille Inlet 2 7 8 73 5 2 7 8 73 5 Air outlet Hanger Hanger Hanger 10 5 16 262 5 10 5 16 262 5 Outline of indoor unit For stud bold Ø5 16 8 Ø13 32 10 10 9 278 7 9 200 8 7 222 7 9 200 5 9 150 20 7 525 5 2 132 1 9 16 47 6 1 32 154 4...

Страница 4: ...Detail A Rear Leg R7 32 R5 5 Ø1 4 Hole Ø6 Hole Ø1 4 Hole Ø6 Hole Ø7 16x9 16 Oval Hole Ø11x14 Oval Hole Detail B Front Leg COVER PACKED VALVE View Z WIRE GUARD View Z Liquid side Flare Nut Ø1 4 Ø6 35 Gas side Flare Nut Ø1 2 Ø12 7 Service Port Air Inlet Air Outlet 3 15 16 or more 100 mm or more 23 5 8 or more 600 mm or more 2 R7 32x43 64L R5 5x17L U Shape For Ø5 16 Ø13 32 Ø8 Ø10 Anchor Bolt 2 Ø7 16x...

Страница 5: ...components The power supply shall be connected to the outdoor unit by 3 wires The connecting cable between the indoor unit and outdoor unit needs to have 4 wires This cable provides the power for the indoor unit and the communication signal between the outdoor unit and indoor unit Consult local building codes NEC National Electrical Code or CEC Canadian Electrical Code for special requirements The...

Страница 6: ...IS MIXED WITH THE REFRIGERANT THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS IN THE EVENT OF REFRIGERANT LEAKAGE DURING INSTALLATION ALLOW FRESH AIR INTO THE ROOM IMMEDIATELY IF THE REFRIGERANT GAS IS HEATED BY FIRE OR OTHER MEAN IT GENERATES POISONOUS GAS Installing staring up and servicing air conditioning e...

Страница 7: ...t can sufficiently bear its weight If the load bearing of the unit is not enough or installation of the unit is improper the unit may fall and result in injury Electrical work must be performed by trained qualified installers and service mechanics in accordance with the code governing such installation work internal wiring regulations and the manual A dedicated circuit and the rated voltage must b...

Страница 8: ...ial polyethylene foam 5 16 in 8 mm thick 1 C Putty PVC tapes One each Field Supplied Installation Parts Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong winds Use Ø5 16 in Ø8 mm or Ø3 8 in Ø10 mm anchor bolts and nuts Fixing bolt arrangement of outdoor unit 4 1 4 in 108 mm 1 1 8 in 28 mm 4 15 16 in 125 mm Ø 1 in 2 5 m m Air inlet Air outlet 3 3 8 i...

Страница 9: ...oor unit from snow accumulation install a holding frame and attach a snow protection hood and plate Do not use a double stacked design Precautions about Installation in Regions with Snowfall and Cold Temperatures Snow protection plate Snow protection hood Snow accumulation line Holding frame At least 19 11 16 in 500 mm Install the unit at least 19 11 16 in 500 mm above the snow accumulation line A...

Страница 10: ... 9 1 6 in 6 5 m m 1 in 23 mm 5 in 132 mm 7 in 170 mm 2 in 50 mm 1 1 2 in 40 mm Stripping length of the Power supply cord and Interconnecting cable L1 L2 L1 L2 S Interconnecting cable Power supply cord Terminal block Unit inch mm L1 L2 L1 L2 S Ground line Connecting cable Power cord Ground line 3 8 10 3 8 10 1 3 16 30 2 12 16 70 3 8 10 3 8 10 1 3 16 30 1 9 16 40 Conduit plate Connector Lock nut Val...

Страница 11: ...itations Fig 2 Fig 1 Construction L1 L2 S L1 L2 S Cord clamp Terminal block Terminal cover Screw Ground line Screw Connecting cable Front panel Fig 3 Wiring CAUTION Failure to firmly install the unit may result in personal injury and property damage if the unit falls In case the unit is to be installed in a block brick concrete or similar type walls make 3 16 in 5 mm dia holes in the wall Insert c...

Страница 12: ...ch a case use the provided screws to fix the unit to the mounting plate Firmly insert the drain hose and drain cap otherwise water may leak In case of right or left piping After making slits of the front panel with a knife or a making off pin cut them with a pair of nippers or an equivalent tool In case of bottom right or bottom left piping After making slits of the front panel with a knife or a m...

Страница 13: ...ontrol with the tip of a pencil 00 will be shown on the display 4 Press MODE while pushing CHK B will show on the display and 00 will disappear and the air conditioner will turn OFF B is now memorized Note 1 Repeat above step to reset Remote Control back to A 2 Remote Control does not display A 3 Default setting of Remote Control from factory is A B Display 00 Display Evacuating After the piping h...

Страница 14: ...indoor unit for 3 seconds to cancel the operation 3 beeps will sound but OPERATION lamp does not blink 2 Press and hold the RESET button on the indoor unit for 3 seconds to set the operation 3 beeps will sound and OPERATION lamp blink 5 time sec for 5 seconds Do not operate ON timer and OFF timer Note Default setting of auto restart operation is ON Check places with flare nut connections indoor un...

Отзывы: