background image

ENGLISH

ESPAÑOL

FRANÇAIS

Indoor unit
RAS-15, 17, 22EK Series

Outdoor unit
RAS-15, 17, 22EA Series

AIR CONDITIONER

 

(SPLIT TYPE)

INSTALLATION MANUAL

1110651824-

1

1110651824-1 EN.indd   1

1110651824-1 EN.indd   1

11/13/13   2:02 PM

11/13/13   2:02 PM

Содержание Carrier RAS-15

Страница 1: ...FRANÇAIS Indoor unit RAS 15 17 22EK Series Outdoor unit RAS 15 17 22EA Series AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL 1110651824 1 1110651824 1 EN indd 1 1110651824 1 EN indd 1 11 13 13 2 02 PM 11 13 13 2 02 PM ...

Страница 2: ...jo Eléctrico 7 UNIDAD INTERIOR 8 Situación de Instalación 8 Corte de un Orificio y Montaje de la Placa de Montaje 8 Conexión de Cables 9 Instalación la Tubería y el Tubo de Desagüe 9 Instalación de la Unidad Interior 10 Drenaje 11 Mando a distancia A B Selección 11 EVACUACIÓN 11 Evacuación 11 OTROS 12 Comprobación de Fugas 12 Prueba de Operación 12 Ajuste de Reinicio Automático 12 Troubleshooting ...

Страница 3: ... 4 6 35 Drain hose 19 11 16 0 5m Connecting pipe 15 5 16 0 39m Flare Ø1 2 12 70 For stud bold Ø2 1 4 6 8 15 32 215 5 Hanger Hanger Center line Installation plate outline Grille Inlet 2 7 8 73 5 2 7 8 73 5 Air outlet Hanger Hanger Hanger 10 5 16 262 5 10 5 16 262 5 Outline of indoor unit For stud bold Ø5 16 8 Ø13 32 10 10 9 278 7 9 200 8 7 222 7 9 200 5 9 150 20 7 525 5 2 132 1 9 16 47 6 1 32 154 4...

Страница 4: ...Detail A Rear Leg R7 32 R5 5 Ø1 4 Hole Ø6 Hole Ø1 4 Hole Ø6 Hole Ø7 16x9 16 Oval Hole Ø11x14 Oval Hole Detail B Front Leg COVER PACKED VALVE View Z WIRE GUARD View Z Liquid side Flare Nut Ø1 4 Ø6 35 Gas side Flare Nut Ø1 2 Ø12 7 Service Port Air Inlet Air Outlet 3 15 16 or more 100 mm or more 23 5 8 or more 600 mm or more 2 R7 32x43 64L R5 5x17L U Shape For Ø5 16 Ø13 32 Ø8 Ø10 Anchor Bolt 2 Ø7 16x...

Страница 5: ...components The power supply shall be connected to the outdoor unit by 3 wires The connecting cable between the indoor unit and outdoor unit needs to have 4 wires This cable provides the power for the indoor unit and the communication signal between the outdoor unit and indoor unit Consult local building codes NEC National Electrical Code or CEC Canadian Electrical Code for special requirements The...

Страница 6: ...IS MIXED WITH THE REFRIGERANT THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST OF THE PIPE AND INJURIES ON PERSONS IN THE EVENT OF REFRIGERANT LEAKAGE DURING INSTALLATION ALLOW FRESH AIR INTO THE ROOM IMMEDIATELY IF THE REFRIGERANT GAS IS HEATED BY FIRE OR OTHER MEAN IT GENERATES POISONOUS GAS Installing staring up and servicing air conditioning e...

Страница 7: ...t can sufficiently bear its weight If the load bearing of the unit is not enough or installation of the unit is improper the unit may fall and result in injury Electrical work must be performed by trained qualified installers and service mechanics in accordance with the code governing such installation work internal wiring regulations and the manual A dedicated circuit and the rated voltage must b...

Страница 8: ...ial polyethylene foam 5 16 in 8 mm thick 1 C Putty PVC tapes One each Field Supplied Installation Parts Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong winds Use Ø5 16 in Ø8 mm or Ø3 8 in Ø10 mm anchor bolts and nuts Fixing bolt arrangement of outdoor unit 4 1 4 in 108 mm 1 1 8 in 28 mm 4 15 16 in 125 mm Ø 1 in 2 5 m m Air inlet Air outlet 3 3 8 i...

Страница 9: ...oor unit from snow accumulation install a holding frame and attach a snow protection hood and plate Do not use a double stacked design Precautions about Installation in Regions with Snowfall and Cold Temperatures Snow protection plate Snow protection hood Snow accumulation line Holding frame At least 19 11 16 in 500 mm Install the unit at least 19 11 16 in 500 mm above the snow accumulation line A...

Страница 10: ... 9 1 6 in 6 5 m m 1 in 23 mm 5 in 132 mm 7 in 170 mm 2 in 50 mm 1 1 2 in 40 mm Stripping length of the Power supply cord and Interconnecting cable L1 L2 L1 L2 S Interconnecting cable Power supply cord Terminal block Unit inch mm L1 L2 L1 L2 S Ground line Connecting cable Power cord Ground line 3 8 10 3 8 10 1 3 16 30 2 12 16 70 3 8 10 3 8 10 1 3 16 30 1 9 16 40 Conduit plate Connector Lock nut Val...

Страница 11: ...itations Fig 2 Fig 1 Construction L1 L2 S L1 L2 S Cord clamp Terminal block Terminal cover Screw Ground line Screw Connecting cable Front panel Fig 3 Wiring CAUTION Failure to firmly install the unit may result in personal injury and property damage if the unit falls In case the unit is to be installed in a block brick concrete or similar type walls make 3 16 in 5 mm dia holes in the wall Insert c...

Страница 12: ...ch a case use the provided screws to fix the unit to the mounting plate Firmly insert the drain hose and drain cap otherwise water may leak In case of right or left piping After making slits of the front panel with a knife or a making off pin cut them with a pair of nippers or an equivalent tool In case of bottom right or bottom left piping After making slits of the front panel with a knife or a m...

Страница 13: ...ontrol with the tip of a pencil 00 will be shown on the display 4 Press MODE while pushing CHK B will show on the display and 00 will disappear and the air conditioner will turn OFF B is now memorized Note 1 Repeat above step to reset Remote Control back to A 2 Remote Control does not display A 3 Default setting of Remote Control from factory is A B Display 00 Display Evacuating After the piping h...

Страница 14: ...indoor unit for 3 seconds to cancel the operation 3 beeps will sound but OPERATION lamp does not blink 2 Press and hold the RESET button on the indoor unit for 3 seconds to set the operation 3 beeps will sound and OPERATION lamp blink 5 time sec for 5 seconds Do not operate ON timer and OFF timer Note Default setting of auto restart operation is ON Check places with flare nut connections indoor un...

Отзывы: