63 / 65
D4223121B
Copyright © 2013 TOSHIBA TELI CORPORATION, All rights reserved.
www.toshiba-teli.co.jp
●
Note
In Bulk function, you may want to set “Continuous” to “AcquisitionMode” register.
You can set “MultiFrame”, but acquisition frame number is limited by “AcquisitionFrameCount.
Trigger
Exposure
AcquisitionMode = MultiFrame
AcquisitionFrameCount = 2
TriggerMode = On
TriggerSequence = 6
TriggerAdditionalParameter = 3
Acquisition
Command
Start
Frame 1
Frame 2
Frame 3
The trigger can be input in arbitrary timing.
VD
AcquisitionFrameRate
Stop
Start
Frame 1
Counter is reset.
USB Bus
Frame 1
Frame 1
*Exposure time is determined by ExposureTime setting.
TriggerAdditionalParameter
AcquisitionFrameCount
Stream
stops
This exposure is
discarded.
Frame 2
*Exposure overlaps sensor readout.