5. SYSTEM MODE
EO18-33027
5.11 RFID Module Setting
5-87
5.11.1 TEST
The following item related test is displayed.
・
ID READ
5.11.1.1
ID READ
The printer enters the read test mode, and a read test is performed each time the [ENTER] key is
pressed. When the data of a tag can be read, it is displayed on the LCD.
When the read test failed, the following message is displayed on the LCD.
Error message
Error description
MODULE TYPE ERROR
RFID module type has been set to NONE or a
communication cannot be established.
COUNTRY CONFIG ERROR
Country/region code has not been set.
READ ERROR
Confirm Setting or
set other Tag.
The type of the tag to be read and one selected by the
RFID tag type selection do not match.
NOT AVAILABLE
Not supported.
NO RESPONSE
No response from the tag
READ TIMEOUT
Set a RF-Tag on Ant.
Timeout
UNKNOWN ERROR
Other errors
Only the tags selected for the RFID tag type can be read.
If the type of the tag to be read and one selected by the RFID tag type selection do not match, the
read test results in an error. Therefore, RFID tag type shall be selected before the read test is started.
・
Display example
Display
(1) The number tag being read/The total number of tags read
(
Mostly, only 1 tag is read.
)
(2) For the UHF module, AGC value of the read tag is displayed with decimal number.
(3) Data displayed on 3rd and 4th lines are expressed with hex. code.
(1)
(2)
(3)