5. SYSTEM MODE
EO18-33027
5.5 ADJUST SET
5-57
5.5.7.2 RBN ADJ.<FW>
5.5.7.2.1 TYPE1
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
10
-15
1
Decimal
Exist
2
0
None
Step
The fine adjustment value is not effective for the reverse rotation.
The fine adjustment value for the ribbon take-up motor is limited depending on the print speed.
Print speed
6 ips or slower
8 ips
10 ips or faster
Fine adjustment value
-15 to +10
-15 to +5
-15 to 0
5.5.7.2.2 TYPE2
Max. value Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
10
-15
1
Decimal
Exist
2
0
None
Step
The fine adjustment value is not effective for the reverse rotation.
The fine adjustment value for the ribbon take-up motor is limited depending on the print speed.
Print speed
6 ips or slower
8 ips
10 ips or faster
Fine adjustment value
-15 to +10
-15 to +5
-15 to 0
5.5.8 RBN ADJ.<BK>
Max.
value
Min. value
Step
Display
Sign
Integer
digit
Decimal
place
0-padding
Unit of
measure
10
-15
1
Decimal
Exist
2
0
None
Step
The fine adjustment value is not effective for the reverse rotation.
All fine adjustment values are applicable to every print speed.
NOTE: Since the B-EX4D2 is a direct thermal printer, this parameter is displayed but not used for actual
printing.
*1: For the B-EX4T1-TS25-R firmware version V2.0 or later, each time the fine adjustment value is
changed by one, the factor changes by 3%, in the case the factor of fine adjustment value “+5” is
100%.
B-EX4T1-TS25-R V2.0 or later
Fine adjustment value
Factor
*1
Fine adjustment value
Factor
*1
+10
115%
-3
76%
+9
112%
-4
73%
+8
109%
-5
70%
+7
106%
-6
67%
+6
103%
-7
64%
+5
100%
-8
61%
+4
97%
-9
58%
+3
94%
-10
55%
+2
91%
-11
52%
+1
88%
-12
49%
0
85%
-13
46%