SPECIFIC INFORMA
TIONS
– 14 –
CHAPTER 2
SPECIFIC INFORMATIONS
SETTING & ADJUSTING DATA
SAFETY INSTRUCTIONS
SERVICE MODE
ADJUSTING ITEMS AND DATAS IN THE SERVICE MODE:
Table-1
Table-2
29"
HIGH VOLTAGE AT MAX BEAM CURRENT:
(A)
30.0 kV
MAX HIGH VOLTAGE:
(B)
32.0 kV
AC VOLTAGE
(C) 110-240 V
BCUT
B CUTOFF (B/W)
20H
←
GCUT
G CUTOFF (B/W)
20H
←
RDRV
R DRIVE
20H
←
GDRV
G DRIVE
20H
←
BDRV
B DRIVE
20H
←
BRTC
SUB BRIGHT CENTER
24H
←
COLC
SUB COLOR CENTER NTSC
1EH
←
TNTC
SUB TINT CENTER
1EH
←
COLP
SUB COLOR CENTER PAL
1DH
←
COLS
SUB COLOR CENTER SECAM
1DH
←
SCNT
SUB CONTRAST TV
00H
←
SBY
SECAM B-Y BLACK OFFSET
01H
←
VPOS
50Hz V-POSITION
1CH
←
HIT
HEIGHT
25H
←
VLIN
V-LINEARITY
24H
←
HPOS
H-POSITION
2BH
←
WID
EW WIDTH
31H
←
PARA
EW PARABOLA
17H
←
TRAP
EW TRAPEZIUM
26H
←
TCNR
EW UPPER PARABOLA
15H
←
BCNR
EW LOWER PARABOLA
15H
←
HPLL
HORIZONTAL PARALLELOGRAM
22H
←
HBOW HORIZONTAL BOW
20H
←
XCAL
CRYSTAL CALIBRATION
30H
←
RAGC
AGC TAKE-OVER
12H
←
CTR1
CONTROL 1
07H
←
Item
Adjustment
Reference Data
Adjust Data
Содержание 29CZ5DE
Страница 32: ... 34 ...