September 1997 © TOSHIBA CORP.
1 - 11
2460 ADJUSTMENT
Initial
Operation
Code
Adjustment
Mode
value
Allowance
Contents
procedure
group
200
Auto-toner automatic adjustment
ALL
–
–
• Increasing the value increases
the sensor output.
• The output is set in the range
of 2.35~2.45V automatically
after changing the value and
2 minutes after starting this
mode.
(Note 1)
201
Auto-toner manual adjustment
ALL
128
0~255
The auto toner sensor adjust-
2
ment value can be displayed.
205
Developer bias, DC adjustment
ALL
174
0~255
The transformer output is aug-
2
210
Grid voltage initial value adjustment
ALL
114
0~255
mented by increasing the value
220
Transfer, DC output, High, adjustment
ALL
125
0~255
by “1”.
221
Transfer, DC output, Center, adjustment
ALL
75
0~255
222
Transfer, DC output, Low, adjustment
ALL
75
0~255
230
Separation, AC output, High, adjustment
ALL
156
0~255
231
Separation, AC output, Center, adjustment
ALL
156
0~255
232
Separation, AC output, Low, adjustment
ALL
62
0~255
240
Pre-Cleaning Discharge, AC output adjustment
ALL
142
0~255
(Note 2)
261
Laser power, 600 dpi, initial value adjustment
ALL
58
0~255
2
304
Scanner secondary scanning reproduction ratio Standard PPC 128
0~255
If the value is increased by “1”,
1
the reproduction ratio of the
paper feeding direction is en-
larged by approx. 0.1522%.
305
Scanner secondary scanning deviation
ALL
135
85~171
If the value is increased by “1”,
1
the image shifts approx. 0.1213
mm to the trailing edge of the
paper.
306
CCD primary scanning deviation
ALL
85
5~251
If the value is increased by “1”,
1
the image shifts approx. 0.0423
mm to the front side.
310
Halogen lamp light on voltage setting
ALL
55
50~70
3
313
Original leading edge image deletion
Standard PPC 128
128~255 If the value is increased by “1”,
1
the leading edge void is enlarged
by approx. 0.1213 mm for a
standard copy.
314
Original leading edge image deletion
Extended PPC 128
128~255 If the value is increased by “1”,
1
the leading edge deletion is en-
larged by approx. 0.1213 mm
for a special function copy.
1.2.4
Adjustment mode (05)
In this mode, the following adjustment items can be corrected or changed. To access this code, turn on
the power while pressing the “0” and “5” keys.
(Note 1): Refer to 1.3.
(Note 2): Functional with the developer unit removed and the service jig attached. However, the jig is not necessary for the devel-
oper bias adjustment. Refer to 1.9.