2

REQUIREMENT OF REPORT TO THE LOCAL POWER SUPPLIER

Please make absolutely sure that the installation of this appliance is reported to the local power supplier before installation. If you experience any problems 
or if the installation is not accepted by the supplier, the service agency will take adequate countermeasures.

CAUTION

•  Exposure of unit to water or other moisture before installation could result in electric shock. Do not store it in a wet basement or expose to rain or water.
•  After unpacking the unit, examine it carefully for possible damage.
•  Do not install in a place that can increase the vibration of the unit. Do not install in a place that can amplify the noise level of the unit or where noise and 

discharged air might disturb neighbors.

•  Please read this installation manual carefully before installing the unit. It contains further important instructions for proper installation.
•  This appliance must be connected to the main power supply by means of a circuit breaker depending on the place where the unit is installed. Failure to do 

so may cause electrical shock. 

•  Follow the instructions in this installation manual to arrange the drain pipe for proper drainage from the unit. Ensure that drained water is discharged. 

Improper drainage can result in water leakage, causing water damage to furniture.

•  Tighten the 

fl

 are nut with a torque wrench using the prescribed method. Do not apply excess torque. Otherwise, the nut may crack after a long period of 

usage and it may cause the leakage of refrigerant.

•  Wear gloves (heavy gloves such as cotton gloves) for installation work. Failure to do so may cause personal injury when handling parts with sharp edges. 
•  Do not touch the air intake section or the aluminum 

fi

 ns of the outdoor unit. It may cause injury. 

•  Do not install the outdoor unit in a place which can be a nest for small animals. Small animals could enter and contact internal electrical parts, causing a 

failure or 

fi

 re.

•  Request the user to keep the place around the unit tidy and clean.
•  Make sure to conduct a trial operation after the installation work, and explain how to use and maintain the unit to the customer in accordance with the 

manual. Ask the customer to keep the operation manual along with the installation manual.

1110651154-EN.indd   2

1110651154-EN.indd   2

2/15/10   9:39:37 AM

2/15/10   9:39:37 AM

Содержание 22SAV

Страница 1: ...r unit RAS 18 22SKV R Series Outdoor unit RAS 18 22SAV Series AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL 1110651154 Cover 1110651154 indd 1 Cover 1110651154 indd 1 1 22 10 11 14 26 AM 1 22 10 11 14 26 AM ...

Страница 2: ...Installation 5 n Indoor Unit Fixing 6 n Drainage 6 OUTDOOR UNIT 6 n Installation Place 6 n Precautions about Installation in Regions with Snowfall and Cold Temperatures 6 n Refrigerant Piping Connection 7 n Evacuating 7 n Wiring Connection 7 n Electrical Work 7 OTHERS 8 n Gas Leak Test 8 n Remote Control A B Selection 8 n Test Operation 8 n Auto Restart Setting 8 Cover 1110651154 indd 2 Cover 1110...

Страница 3: ...ing in damage to the unit or injury Do not modify the power cable connect the cable midway or use a multiple outlet extension cable Doing so may cause contact failure insulation failure or excess current resulting in fire or electrical shock If you detect any damage do not install the unit Contact your supplying dealer immediately New refrigerant air conditioner installation CAUTION THIS AIR CONDI...

Страница 4: ...use electrical shock Follow the instructions in this installation manual to arrange the drain pipe for proper drainage from the unit Ensure that drained water is discharged Improper drainage can result in water leakage causing water damage to furniture Tighten the flare nut with a torque wrench using the prescribed method Do not apply excess torque Otherwise the nut may crack after a long period o...

Страница 5: ...rain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 8 mm thick heat resisting polyethylene foam 1 Batteries Pan head wood screw Remote control holder Vinyl tape Apply after carrying out a drainage test Wireless remote control Saddl...

Страница 6: ...he pipe hole dia 65 mm at a slight downward slant to the outdoor side A place which provides the spaces around the indoor unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor uni...

Страница 7: ...pipe make sure to use a spring bender so as not to crush the pipe Bend the connecting pipe within a radius of 30 mm To connect the pipe after installation of the unit figure How to install the air inlet grille on the indoor unit When attaching the air inlet grille perform the same process as for removal but in reverse order Wiring Connection Wiring of the connecting cable can be carried out withou...

Страница 8: ...cause any problems CAUTION 1 Install the outdoor unit in a location where there are no obstructions near its air intake or air outlet 2 When the outdoor unit is installed in a place that is always exposed to strong winds like on the coast or on a high story of a building secure the normal fan operation using a duct or a wind shield 3 Especially in windy areas install the unit to prevent the admiss...

Страница 9: ...uid side Service port Valve core Setting pin Packed valve at gas side Vacuum pump Vacuum pump adapter for counter flow prevention For R410A only Charge hose For R410A only Handle Hi Keep full closed Manifold valve Pressure gauge Compound pressure gauge Handle Lo Charge hose For R410A only Connecting pipe 101 kPa 76 cmHg Open the valve stem until it touches the stopper Once it is in contact with th...

Страница 10: ...ns for the gas leak with a gas leak detector or soap water This product is designed so that after a power failure it can restart automatically in the same operating mode as before the power failure 1 Press and hold the RESET button on the indoor unit for 3 seconds to set the operation 3 beep sound and OPERATION lamp blink 5 time sec for 5 seconds 2 Press and hold the RESET button on the indoor uni...

Страница 11: ...Cover back 1110651154 indd 1 Cover back 1110651154 indd 1 1 22 10 11 15 21 AM 1 22 10 11 15 21 AM ...

Страница 12: ...Cover back 1110651154 indd 2 Cover back 1110651154 indd 2 1 22 10 11 15 22 AM 1 22 10 11 15 22 AM ...

Отзывы: