PRECAUTIONS FOR SAFETY

PRECAUTIONS FOR SAFETY

WARNING

•  Never modify this unit by removing any of the safety guards or bypassing any of the safety interlock switches.
•  Installation work must be requested from the supplying retail dealership or professional vendors. Self-installation may cause water leakage, electrical 

shock, or 

fi

 re as a result of improper installation.

•  Speci

fi

 ed tools and pipe parts for model R410A are required, and installation work must be done in accordance with the manual. HFC type refrigerant 

R410A has 1.6 times more pressure than that of conventional refrigerant (R22). Use the speci

fi

 ed pipe parts, and ensure correct installation, otherwise 

damage and/or injury may be caused. At the same time, water leakage, electrical shock, and 

fi

 re may occur.

•  Be sure to install the unit in a place which can suf

fi

 ciently bear its weight. If the load bearing of the unit is not enough, or installation of the unit is 

improper, the unit may fall and result in injury. 

•  Electrical work must be performed by a quali

fi

 ed electrical engineer in accordance with the code governing such installation work, internal wiring 

regulations, and the manual. A dedicated circuit and the rated voltage must be used. Insuf

fi

 cient power supply or improper installation may cause 

electrical shock or 

fi

 re.

•  Use a cabtyre cable to connect wires in the indoor/outdoor units. Midway connection, stranded wire, and single-wire connections are not allowed. 

Improper connection or 

fi

 xing may cause a 

fi

 re.

•  Wiring between the indoor unit and outdoor units must be well shaped so that the cover can be 

fi

 rmly placed. Improper cover installation may cause 

increased heat, 

fi

 re, or electrical shock at the terminal area.

•  Be sure to use only approved accessories or the speci

fi

 ed parts. Failure to do so may cause the unit to fall, water leakage, 

fi

 re or electrical shock.

•  After the installation work, ensure that there is no leakage of refrigerant gas. If the refrigerant gas leaks out of the pipe into the room and is heated by 

fi

 re or something else from a fanheater, stove or gas range, it causes generation of poisonous gas.

•  Make sure the equipment is properly earthed. Do not connect the earth wire to a gas pipe, water pipe, lightning conductor, or telephone earth wire. 

Improper earth work may be the cause of electrical shock. 

•  Do not install the unit where 

fl

 ammable gas may leak. If there is any gas leakage or accumulation around the unit, it can cause a 

fi

 re.

•  Do not select a location for installation where there may be excessive water or humidity, such as a bathroom. Deterioration of insulation may cause 

electrical shock or 

fi

 re.

•  Installation work must be performed following the instructions in this installation manual. Improper installation may cause water leakage, electrical shock 

or 

fi

 re. Check the following items before operating the unit.

  -  Be sure that the pipe connection is well placed and there are no leaks.
  -  Check that the service valve is open. If the service valve is closed, it may cause overpressure and result in compressor damage. At the same time, if 

there is a leak in the connection part, it may cause air suction and overpressure, resulting in damage to the unit or injury.

•  In a pump-down operation, be sure to stop the compressor unit before removing the refrigerant pipe. If removing the refrigerant pipe while the 

compressor is operating with the service valve opened, it may cause air suction and overpressure, resulting in damage to the unit or injury.

•  Do not modify the power cable, connect the cable midway, or use a multiple outlet extension cable. Doing so may cause contact failure, insulation 

failure, or excess current, resulting in 

fi

 re or electrical shock.

•  If you detect any damage, do not install the unit. Contact your supplying dealer immediately.

New refrigerant air conditioner installation

CAUTION

• 

THIS AIR CONDITIONER USES THE NEW HFC REFRIGERANT (R410A), WHICH DOES NOT DESTROY THE OZONE LAYER.

 

R410A refrigerant is apt to be affected by impurities such as water, oxidizing membranes, and oils because the pressure of R410A refrigerant is approx. 
1.6 times of refrigerant R22. As well as the adoption of this new refrigerant, refrigerating machine oil has also been changed. Therefore, during installation 
work, be sure that water, dust, former refrigerant, or refrigerating machine oil does not enter the refrigeration cycle of a new-refrigerant air conditioner.

  To avoid mixing refrigerant and refrigerating machine oil, the sizes of charging port connecting sections on the main unit are different from those for the 

conventional refrigerant, and different size tools are also required. For connecting pipes, use new and clean piping materials with highpressure withstand 
capabilities, designed for R410A only, and ensure that water or dust does not enter. Moreover, do not use any existing piping as its pressure withstand 
may be insuf

fi

 cient and may contain impurities.

DANGER

•  FOR USE BY QUALIFIED PERSONS ONLY.
•  TURN OFF MAIN POWER SUPPLY BEFORE ATTEMPTING ANY ELECTRICAL WORK. MAKE SURE ALL POWER SWITCHES ARE OFF.
  FAILURE TO DO SO MAY CAUSE ELECTRIC SHOCK.
•  CONNECT THE CONNECTING CABLE CORRECTLY. IF THE CONNECTING CABLE IS CONNECTED WRONGLY, ELECTRIC PARTS MAY BE 

DAMAGED.

•  CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION.
•  DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS.
  FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION.
•  TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD, PLACE THE UNIT WELL AWAY (MORE THAN 2 M) FROM HEAT 

SOURCES SUCH AS RADIATORS, HEATERS, FURNACE, STOVES, ETC.

•  WHEN MOVING THE AIR CONDITIONER FOR INSTALLING IT IN ANOTHER PLACE AGAIN, BE VERY CAREFUL NOT TO GET THE SPECIFIED 

REFRIGERANT (R410A) WITH ANY OTHER GASEOUS BODY INTO THE REFRIGERATION CYCLE. IF AIR OR ANY OTHER GAS IS MIXED IN THE 
REFRIGERANT, THE GAS PRESSURE IN THE REFRIGERATION CYCLE BECOMES ABNORMALLY HIGH AND IT RESULTINGLY CAUSES BURST 
OF THE PIPE AND INJURIES ON PERSONS.

•  IN THE EVENT THAT THE REFRIGERANT GAS LEAKS OUT OF THE PIPE DURING THE INSTALLATION WORK, IMMEDIATELY LET FRESH AIR 

INTO THE ROOM. IF THE REFRIGERANT GAS IS HEATED BY FIRE OR SOMETHING ELSE, IT CAUSES GENERATION OF POISONOUS GAS.

For general public use

Power supply cord of parts of appliance for outdoor use shall be at least polychloroprene sheathed 

fl

 exible cord (design H07RN-F) or cord designation 

60245 IEC66 (1.5 mm

2

 or more). (Shall be installed in accordance with national wiring regulations.)

•  Before installation, please read these precautions for safety carefully.
•  Be sure to follow the precautions provided here to avoid safety risks. The symbols and their meanings are shown below.

WARNING :

  It indicates that incorrect use of this unit may cause severe injury or death. 

 

CAUTION :

  It indicates that incorrect use of this unit may cause personal injury (*1), or property damage (*2).

 

  *1: Personal injury means a slight accident, burn, or electrical shock which does not require admission or repeated hospital treatment.

 

  *2: Property damage means greater damage which affects assets or resources.

1110651154-EN.indd   1

1110651154-EN.indd   1

2/15/10   9:39:36 AM

2/15/10   9:39:36 AM

Содержание 22SAV

Страница 1: ...r unit RAS 18 22SKV R Series Outdoor unit RAS 18 22SAV Series AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL 1110651154 Cover 1110651154 indd 1 Cover 1110651154 indd 1 1 22 10 11 14 26 AM 1 22 10 11 14 26 AM ...

Страница 2: ...Installation 5 n Indoor Unit Fixing 6 n Drainage 6 OUTDOOR UNIT 6 n Installation Place 6 n Precautions about Installation in Regions with Snowfall and Cold Temperatures 6 n Refrigerant Piping Connection 7 n Evacuating 7 n Wiring Connection 7 n Electrical Work 7 OTHERS 8 n Gas Leak Test 8 n Remote Control A B Selection 8 n Test Operation 8 n Auto Restart Setting 8 Cover 1110651154 indd 2 Cover 1110...

Страница 3: ...ing in damage to the unit or injury Do not modify the power cable connect the cable midway or use a multiple outlet extension cable Doing so may cause contact failure insulation failure or excess current resulting in fire or electrical shock If you detect any damage do not install the unit Contact your supplying dealer immediately New refrigerant air conditioner installation CAUTION THIS AIR CONDI...

Страница 4: ...use electrical shock Follow the instructions in this installation manual to arrange the drain pipe for proper drainage from the unit Ensure that drained water is discharged Improper drainage can result in water leakage causing water damage to furniture Tighten the flare nut with a torque wrench using the prescribed method Do not apply excess torque Otherwise the nut may crack after a long period o...

Страница 5: ...rain hose to get slack Cut the piping hole sloped slightly The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Right Rear right Bottom right Rear left Bottom left Left 8 mm thick heat resisting polyethylene foam 1 Batteries Pan head wood screw Remote control holder Vinyl tape Apply after carrying out a drainage test Wireless remote control Saddl...

Страница 6: ...he pipe hole dia 65 mm at a slight downward slant to the outdoor side A place which provides the spaces around the indoor unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed as top of the indoor uni...

Страница 7: ...pipe make sure to use a spring bender so as not to crush the pipe Bend the connecting pipe within a radius of 30 mm To connect the pipe after installation of the unit figure How to install the air inlet grille on the indoor unit When attaching the air inlet grille perform the same process as for removal but in reverse order Wiring Connection Wiring of the connecting cable can be carried out withou...

Страница 8: ...cause any problems CAUTION 1 Install the outdoor unit in a location where there are no obstructions near its air intake or air outlet 2 When the outdoor unit is installed in a place that is always exposed to strong winds like on the coast or on a high story of a building secure the normal fan operation using a duct or a wind shield 3 Especially in windy areas install the unit to prevent the admiss...

Страница 9: ...uid side Service port Valve core Setting pin Packed valve at gas side Vacuum pump Vacuum pump adapter for counter flow prevention For R410A only Charge hose For R410A only Handle Hi Keep full closed Manifold valve Pressure gauge Compound pressure gauge Handle Lo Charge hose For R410A only Connecting pipe 101 kPa 76 cmHg Open the valve stem until it touches the stopper Once it is in contact with th...

Страница 10: ...ns for the gas leak with a gas leak detector or soap water This product is designed so that after a power failure it can restart automatically in the same operating mode as before the power failure 1 Press and hold the RESET button on the indoor unit for 3 seconds to set the operation 3 beep sound and OPERATION lamp blink 5 time sec for 5 seconds 2 Press and hold the RESET button on the indoor uni...

Страница 11: ...Cover back 1110651154 indd 1 Cover back 1110651154 indd 1 1 22 10 11 15 21 AM 1 22 10 11 15 21 AM ...

Страница 12: ...Cover back 1110651154 indd 2 Cover back 1110651154 indd 2 1 22 10 11 15 22 AM 1 22 10 11 15 22 AM ...

Отзывы: