1 - 27
Oct. 1995 © TOSHIBA CORP.
1550 ADJUSTMENT
1
Perform the 100% manual exposure adjustment (3)-
1
.
2
154% manual exposure adjustment
Sequence
Operation
Display after operation (typical)
2-1
2-2
2-3
2-4
2-5
Input code “2” using the digital keys, and press the “Print” key.
[When density is high]
Increase the numerical value, using the “Zoom” key.
[When density is low]
Decrease the numerical value, using the “Zoom” key.
Press the “Interrupt” key and store the numerical value in the
memory.
Press the “Energy saver” key and make a test copy.
If the image density of the test copy is not satisfactory, repeat
operations 2-1 through 2-4.
130
149
126
14
4
424
4
43
3
50% manual exposure adjustment
Sequence
Operation
Display after operation (typical)
3-1
3-2
3-3
3-4
3-5
Input code “3” using the digital keys, and press the “Print” key.
[When density is high]
Increase the numerical value, using the “Zoom” key.
[When density is low]
Decrease the numerical value, using the “Zoom” key.
Press the “Interrupt” key and store the numerical value in the
memory.
Press the “Energy saver” key and make a test copy.
If the image density of the test copy is not satisfactory, repeat
operations 3-1 through 3-4.
103
109
096
14
4
424
4
43
4
200% manual exposure adjustment
Sequence
Operation
Display after operation (typical)
4-1
4-2
4-3
4-4
4-5
Input code “4” using the digital keys, and press the “Print” key.
[When density is high]
Increase the numerical value, using the “Zoom” key.
[When density is low]
Decrease the numerical value, using the “Zoom” key.
Press the “Interrupt” key and store the numerical value in the
memory.
Press the “Energy saver” key and make a test copy.
If the image density of the test copy is not satisfactory, repeat
operations 4-1 through 4-4.
175
186
166
14
4
424
4
43
AJ
AJ
AJ