Torus Power AVR ELITE SERIES Overview

 

Torus Power AVR ELITE models deliver clean AC power with noise attenuation from 2 KHz to beyond 1 MHz. They 

provide true isolation (using large toroidal transformers) along with low source impedance and high 

instantaneous current for today’s most sophisticated and powerful audio amplifiers. The performance level is far 

beyond what any typical power conditioner using discrete filters can provide. 
Torus Power AVR ELITE series products are full-feature state-of-the art power transformers and voltage 

stabilizers, with a built-in web browser interface for Local Area Network and Cloud based connectivity for 

monitoring and control of audio/video systems. It is not necessary to use either as the AVR ELITE provides all the 

standard features, performance, and benefits right out of the box. 
The AVR ELITE series provides multiple output zones that can be separately turned on or off through the web 

browser or via user defined schedules. A key feature is the voltage stabilization that keeps an optimal output 

voltage range (North America /- 4V, Europe/Asia/Aus/- 8V of nominal operating voltage) 

regardless of fluctuations in the line voltage. Voltage sags, brownouts, and surges can stress components and 

shorten equipment life with worst case catastrophic events destroying valuable equipment. In such real world 

conditions, the Torus Power AVR ELITE can protect your equipment and improve the quality of your audio and 

video experience. 
Series mode surge suppression is built into each AVR ELITE to provide protection against lightning strikes and 

other power disturbances, meeting IEEE endurance standards of 6000 volts, 3000 amps, with 1000 repeats. 

Summary of AVR ELITE Series Features 

•  Toroidal isolation provides ultimate clean power performance 
•  Automatic voltage regulation with 4V increments maintains stable voltage output 
•  Series mode surge suppression protects against lighting, surges, spikes etc. 
•  Connect to local network using Web page browser 
•  Addressable outlet zones for control and monitoring 
•  Scheduling and sequencing of outlet zones 
•  Password control 
•  Email notification of fault conditions 
•  No programming or internet connection needed (required if using Torus Power Connect service) 
•  Powerful 32-bit processor 
•  Large graphical display of key power parameters 
•  Internal Flash Memory for 10,000 events to record data when cloud unavailable 
•  Internal high reliability power supply module 
•  Enhanced communication module including WiFi connectivity 
•  USB 2.0 port for 3rd party connectivity, LED lighting, and charging  
•  Optical isolation between high voltage and low voltage to increase safety and compliance to new standards 

Содержание WM 40 BAL AVR-2 ELITE

Страница 1: ...WM AVR 2 ELITE Series Owner s Manual ...

Страница 2: ...wer line noise artifacts are eliminated through the toroidal isolation transformer using patented Narrow Bandwidth Technology The toroidal isolation transformer provides high levels of instantaneous current making sure even dynamic components such as high power amplifiers are never starved for power It s like having a clean power source directly adjacent to the plugged in components Torus Power is...

Страница 3: ...11 North American Models 11 International Models 12 Circuit Schematics 14 Factory Reset Procedure 15 AVR ELITE Embedded Software 16 Username and Password 16 AVR ELITE Menu Selections 17 Torus Power Connect 21 User Registration 22 Device Registration applies to Self Registered Users only 22 User Menu 23 System Status 23 Live Data 24 Power Control 25 System Setup 26 Historical Charts 28 Historical D...

Страница 4: ... of fatal shock 6 Ventilation The device should always be located in such a way that it maintains proper ventilation It should never be placed in a built in installation or anywhere that may impedethe flow of air through its ventilation slots 7 Heat Never locate the device near heat sources suchas radiators floor registers stoves or other heat generating devices 8 Power Cord Protection Power cable...

Страница 5: ...esponsible for installing this unit in accordance with all local provincial state and federal electrical code requirements The installation of this unit requires inspection and approval by local safety authority This wall mount unit is not equipped with a power safety interlock Note Circuit schematic drawing is provided for reference only Torus Power WM AVR2 units have no user serviceable parts in...

Страница 6: ...ere are 4 pre punched knockouts along the bottom of the cabinet to accommodate the incoming power source wiring and the output circuit wiring Warranty Torus Power Inc products are warranted to be free from manufacturing defects as follows Five years from the original date of sale for toroidal transformers Two years from the original date of sale for all other components The product warranty includ...

Страница 7: ...ess components and shorten equipment life with worst case catastrophic events destroying valuable equipment In such real world conditions the Torus Power AVR ELITE can protect your equipment and improve the quality of your audio and video experience Series mode surge suppression is built into each AVR ELITE to provide protection against lightning strikes and other power disturbances meeting IEEE e...

Страница 8: ...ach time you push the button the display will show a different feature of the AVR ELITE When you first turn on the AVR ELITE the System Status will appear Each time you push the button it will change from one information screen to another Time Day Date System Status Power Status Active Zones IP and MAC Address ...

Страница 9: ...inute consecutively the AVR ELITE will resume normal operation and the High or Low AC Voltage advisory message will no longer appear on the LCD display The output zones will provide power again and be turned on in sequential order with the delay between zones as defined in System Setup Nominal Input Output Fully Regulated Output Range Auto Shutdown Low Input Voltage Auto Shutdown High Input Voltag...

Страница 10: ...TE will keep the output constant within the rangeof 120 4V with an input voltage of 180V to 260V Between 170V to 180V and between 260V and 270V the regulation will be reduced 4 International models Torus AVR ELITE will keep the output constant within the range of 240 8V with an input voltage of 180V to 260V Between 170V to 180V and between 260V and 270V the regulation will be reduced 5 The output ...

Страница 11: ...mmed Each zone can be scheduled to turn ON or OFF at any time or day of the week Each zone can also be individually turned ON or OFF through the local web browser interface or Torus Power Connect account Zone R can be programmed as either a controlled outlet or an automatically rebooted Router outlet North American Model WM 60 BAL AVR 2 ELITE TVSS Toronto Canada ...

Страница 12: ... E F G in higher capacity units All output zones will be turned to the ON state when the AVR ELITE is turned ON This also applies when output zone s were OFF prior to cycling its main power by turning it OFF and then ON again Routers should be connected to Zone R if the automatic reboot feature is to be utilized if this feature is NOT to be used Zone R can be used as an extra controllable output z...

Страница 13: ... ON the AVR ELITE and removing the 12 volts turns it OFF Requires a 3 5 mm TS type male audio connector with tip wired as positive and sleeve wired as negative from controlling source 12VDC Fault Output The AVR ELITE provides a 12 volt fault output through a jack on the back panel The output goes to 12 volts when a relay or voltage fault is detected The maximum current that can be drawn from this ...

Страница 14: ... AVR 2 ELITE 65 143 82 6 x 62 7 x 26 1 32 5 x 24 7 x 10 3 NEMA Type 1 Enclosure 14 gauge steel black powder coated finish door has turn latch and slip hinges for easy removal WM 60 BAL AVR 2 ELITE 83 182 6 WM 90 BAL AVR 2 ELITE 131 288 2 Surge Suppression Series Mode Surge Suppression SMSS All models include non sacrificial SMSS surge suppression on the output side of the transformer Transient Vol...

Страница 15: ...84 8 82 6 x 62 7 x 26 1 32 5 x 24 7 x 10 3 NEMA Type 1 Enclosure 14 gauge steel black powder coated finish door has turn latch and slip hinges for easy removal WM 45 BAL AVR 2 ELITE 132 290 4 Surge Suppression Series Mode Surge Suppression SMSS All models include non sacrificial SMSS surge suppression on the output side of the transformer Transient Voltage Surge Suppression TVSS TVSS surge suppres...

Страница 16: ...13 P a g e ...

Страница 17: ...14 P a g e Circuit Schematics North American Model WM 60 BAL AVR 2 ELITE TVSS ...

Страница 18: ...for approximately 30 seconds and then release the pushbutton switch 5 Use the pushbutton as you would normally to scroll through the various screens until you get to the IP address screen and it should now show as 0 0 0 0 6 Plug in the Ethernet cable The IP address should change to a value appropriate for your new network setup as the unit s network configuration is now set to factory default as D...

Страница 19: ...en 2 Use a three way DHCP Router You then connect both PC and AVR ELITE to the same DHCP Router Open a browser window from the PC Type AVR or the IP address displayed on the LCD into the browser window Press ENTER and the software will open Username and Password The password is required to change the setup of the Torus unit Username admin The username is factory set and cannot be changed Password ...

Страница 20: ...ctioning normally or whether there is a fault condition No password required to monitor status Switch Main Power This screen allows ON OFF control of the AVR ELITE unit Press the SET button to implement your selection As the output power from the Torus AVR ELITE unit is shut down all the connected equipment is turned off The AVR ELITE main power switch remains in the ON position although there is ...

Страница 21: ...ter entering the configuration parameters use the Send Test Email button to confirm your settings are correct Date and Time Setup When the AVR ELITE is connected to the Internet the date time and day will automatically be set However when the AVR ELITE has no access to the Internet the Date Time and Day can be set manually which will allow the AVR ELITE to follow scheduled programming even if the ...

Страница 22: ...set Zone R will act like a regular zone and can be programmed to switch ON OFFindividually like other zones see page 8 Zone Power Control Zone R works with the Schedule Manager and can be programmed to turn ON OFF atany time on any day of the week like other zones see page 10 Scheduling Management Zone R operates with other zones during sequential start up Checked Zone R Router Reset Zone R can on...

Страница 23: ... Each AVR ELITE unit has a unique MAC Address which is factory assigned The IP address assigned to the AVR ELITE is dynamically assigned and is displayed on this screen as well as on the front panel LCD of the AVR ELITE The AVR ELITE can be programmed through the web browser to automatically get an IP address from the network switch or router and this is the default setting and should work on most...

Страница 24: ...Torus Power Connect provides Users with a custom dashboard for control status setup and configuration purposes One year of Torus Power Connect service is included with each new AVR Elite purchase A subscription renewal is required to continue this service beyond the first year Visit www toruspower com to purchase a 1 2 or 3 year subscription renewal ...

Страница 25: ...ler installer will get the required details to proceed with the registration and activation of this service for your AVR Elite and provide your account login details Device Registration applies to Self Registered Users only Each AVR Elite device to utilize the Torus Power Connect service by the dealer and or user must be registered There is a unique identifier called a MAC address for each AVR Eli...

Страница 26: ...available options Highlight and click to select the desired option see below for details of each option System Status Click the Show text for a specific AVR Elite device to view its system status details This will provide a snapshot of the values at the time of the request Clicking the Refresh text bar will update the System Status details every 3 seconds for 1 minute ...

Страница 27: ...for a specific AVR Elite device to easily view its input voltage output voltage input current output current and output Total Harmonic Distortion values Clicking the Refresh text bar will update the Live Data details every 3 seconds for 1 minute ...

Страница 28: ...the Control text for a specific AVR Elite device to manually control ON OFF the unit s power state or the power state of each individual outlet zone Click the Refresh Reported Values text to confirm the specific action was successful ...

Страница 29: ...ld be cycled if the initial power cycle failed to restore internet connectivity This power cycle will be attempted a maximum of three time This setting requires the Zone R Router Reset box to be checked Delay Time between Zones enter the time in seconds from 1 to 999 for delay between the sequential power up of zones when the AVR Elite unit is turned on or multiple zones are turned on at the same ...

Страница 30: ...27 P a g e ...

Страница 31: ...28 P a g e Historical Charts Click the Plot text for a specific AVR Elite device to Move the mouse cursor to one of the plot points to get the value and time for that data point ...

Страница 32: ...29 P a g e ...

Страница 33: ...st data values and the Requested Interval is the time period duration to be provided The data is listed chronologically in one minute intervals as the default sort order The data can be sorted by the values in any of the columns by clicking on the specific column header e g Output Voltage V The first click on the specific column header will sort the values from highest to lowest Clicking the same ...

Страница 34: ...31 P a g e ...

Страница 35: ... create a scheduled power on or off click the desired day then type in the hour and minutes 24 hour format or use the up down arrows to scroll to the desired value Check the box associated with each zone you wish to have power enabled at its outlets at that time WARNING Leaving a zone s box unchecked for a specific time will turn power off for all the zone s outlets at that time Click the Save Sch...

Страница 36: ...33 P a g e ...

Страница 37: ...t file or a fixed format pdf file The CSV format file can be imported into a spreadsheet software program such as Microsoft Excel so it can be manipulated to filter present the information in the desired format The pdf format file has information presented in a fixed report format The file is sent to the email address entered in the Dealer Information section ...

Страница 38: ...he Personal Information home screen shows the User s contact information submitted during the Torus Power Connect registration The User can use the Change Password text bar at any time to submit a new Torus Power Connect login password ...

Отзывы: