Before you call for service to your authorized distributor, check this manual
again to avoid a misunderstanding.
PROBLEM
POSSIBLE CAUSE
SOLUTION
THE SCALE
NOT
OPERATE
THERE IS NOT ELECTRIC
CURRENT.
WITH A MULTIMETER CHECK THE
CURRENT OUTLETS.
AC/DC POWER SUPPLY
CABLE HAS A FALSE
CONTACT.
CHECK THE AC/DC POWER
SUPPLY TERMINALS, IF IT IS
POSSIBLE, CHECK WITH ANOTHER
AC/DC POWER SUPPLY.
LOW BATTERY.
CONNECT THE AC/DC POWER
SUPPLY IF OPERATES, THEN
REPLACE THE BATTERY.
THE SCALE
SHOWS
DIFFERENT
WEIGHTS
WITH THE
SAME WEIGHT
MATERIAL OBSTRUCTING
THE CORRECT
MOVEMENT.
CHECK IF EXISTS MATERIALS
UNDER
THE PLATFORM. IF SO, REMOVE
THEM AND CHECK THE
OPERATION AGAIN.
TROUBLESHOOTING GUIDE
THE WORD
“HELP”
APPEARS IN
THE
DISPLAY
THE SCALE WAS TURNED
ON WITH A BIG WEIGHT
ON THE PLATE.
REMOVE THE WEIGHT AND
TURN OFF THE SCALE AND THEN
TURN ON IT ON AGAIN.
“UNLOAD”
MESSAGE
APPEARS
ON DISPLAY
WEIGHT BIGGER THAN 20
% OF THE LOAD CELL
CAPACITY
ON
THE
PLATE.
REMOVE THE WEIGHT OF THE
PLATFORM OR LOAD CELL AND
TURN “ON” THE SCALE AGAIN
IMPORTANT NOTE:
•
Storage Temperature: -4
°
F to 122
°
F (-20
°
C a 50
°
C).
•
Input current adapter / Output current adapter: 100 – 240Vac 50/60Hz
/ 9Vdc
Portioning scale
13
Содержание PPC 10/20