16
Operating manual Cruise 2.0
8.3 Connecting the Cruise 2.0 to lead batteries (acid, gel, AGM)
using the Torqeedo cable set
The Cruise 2.0 operates with a power supply of between 20 V and 0 V (relating to the
nominal voltage). That means it can be operated with two serially configured 12 V lead-
acid, lead-gel or AGM batteries.
To increase the capacity, several pairs of serially configured 12 V batteries can be
configured parallel to each other (not recommended - see Basic information on battery
supply).
1. Start by connecting the cable set to the batteries by first connecting the positive pole
of the first battery to the negative pole of the second battery. Use the connecting cable
supplied for this.
2. Make sure the master switch of the cable set is in the off or zero position. If necessary,
switch it to the off or zero position.
. Connect the negative connection terminal of the cable set (identified by the marking) to
the negative pole of the first battery.
4. Then connect the positive connection terminal of the cable set, which includes a fuse,
to the positive pole of the second battery.
5. Now connect the high current plug of the cable set to the high current plug of the
motor.
6. Switch the master switch to the on position. Now your motor is ready to go.
Now the batteries are serially connected to each other: The battery capacity [Wh] and
the voltage [V] of the battery block have been doubled. The battery charge [Ah] is not
changed by serial configuration. (After serial configuration, two serially configured
12 V / 100 Ah batteries, each with 1,200 Wh, have 24 V, 100 Ah and 2,400 Wh.)
The cable set comes complete with a CF8 15 A fuse. In case of a short circuit, the fuse
cuts the circuit and prevents any further damage.