![Toro Workman MD Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/toro/workman-md/workman-md_service-manual_1134463146.webp)
Workman MD/MDX
Page 6 -- 36
Electrical System
Battery Testing
1. Conduct a hydrometer test of the battery electrolyte:
IMPORTANT: Make sure the area around the cells is
clean before opening the battery caps.
A. Measure the specific gravity of each cell with a
hydrometer. Draw electrolyte in and out of the
hydrometer barrel prior to taking a reading to warm--
up the hydrometer. At the same time take the tem-
perature of the cell.
B. Temperature correct each cell reading. For each
10
o
F (5.5
o
C) above 80
o
F (26.7
o
C) add 0.004 to the
specific gravity reading. For each 10
o
F (5.5
o
C) below
80
o
F (26.7
o
C) subtract 0.004 from the specific grav-
ity reading.
Example: Cell Temperature
100
o
F
Cell Gravity
1.245
ADD (20
o
above 80
o
F)
0.008
Correction to 80
o
F
1.253
C. If the difference between the highest and lowest
cell specific gravity is 0.050 or greater or the lowest
cell specific gravity is less than 1.225, charge the bat-
tery. Charge at the recommended rate and time giv-
en in
Charging
or until all cells specific gravity is
1.225 or greater with the difference in specific gravity
between the highest and lowest cell less than 0.050.
If these charging conditions can not be met, replace
the battery.
2. Perform a high--discharge test with an adjustable
load tester.
This is one of the most reliable means of testing a battery
as it simulates the cold--cranking test. A commercial bat-
tery load tester is
required
to perform this test.
CAUTION
Follow the battery load tester manufacturer’s
instructions when using a load tester.
A. Check the voltage across the battery terminals
prior to testing the battery. If the voltage is less than
12.0 VDC, recharge the battery before load testing.
B. Make sure the battery terminals are free of corro-
sion.
C. If the battery has been charged, apply a 150 amp
load for 15 seconds to remove the surface charge.
Use a battery load tester following the manufactur-
er’s instructions.
D. Measure the temperature of the electrolyte in the
center cell.
E. Connect a battery load tester to the battery termi-
nals
following the manufacturer’s instructions
.
Connect a digital multimeter to the battery terminals.
F. Apply a test load of 150 amps (one half the Crank-
ing Performance) for 15 seconds.
G. Take a battery voltage reading at 15 seconds,
then remove the load. Record this test voltage read-
ing.
H. Using the table below, determine the minimum
test voltage for the cell temperature reading.
Minimum
Test Voltage
Battery Electrolyte
Temperature
9.6
70
o
F (and up)
21.1
o
C (and up)
9.5
60
o
F
15.6
o
C
9.4
50
o
F
10.0
o
C
9.3
40
o
F
4.4
o
C
9.1
30
o
F
--1.1
o
C
8.9
20
o
F
--6.7
o
C
8.7
10
o
F
--12.2
o
C
8.5
0
o
F
--17.8
o
C
I. If the test voltage is below the minimum, replace
the battery. If the test voltage is at or above the mini-
mum, return the battery to service.
Содержание Workman MD
Страница 2: ...Workman MD MDX This page is intentionally blank...
Страница 4: ...Workman MD MDX This page is intentionally blank...
Страница 12: ...0 09375 Workman MD MDX Page 2 2 Product Records and Maintenance Equivalents and Conversions...
Страница 36: ...Workman MDX Page 3 20 Briggs Stratton Gasoline Engine This page is intentionally blank...
Страница 42: ...Workman MD Page 4 6 Single Cylinder Gasoline Engine This page is intentionally blank...
Страница 54: ...Workman MD Page 4 18 Single Cylinder Gasoline Engine This page is intentionally blank...
Страница 62: ...Rev A 6 2 Workman MD MDX Drive Train Page 5 This page is intentionally blank...
Страница 71: ...Rev A 13 2 Workman MD MDX Drive Train Page 5 This page is intentionally blank Drive Train...
Страница 77: ...Rev A 15 2 Workman MD MDX Drive Train Page 5 This page is intentionally blank Drive Train...
Страница 81: ...Workman MD MDX Drive Train Page 5 19 This page is intentionally blank Drive Train...
Страница 135: ...Workman MD MDX Page 6 25 Electrical System This page is intentionally blank Electrical System...
Страница 148: ...Workman MD MDX Page 6 38 Electrical System This page is intentionally blank...
Страница 173: ...Workman MD MDX Page 7 25 Chassis This page is intentionally blank Chassis...
Страница 183: ...Workman MD MDX Page 7 35 Chassis This page is intentionally blank Chassis...
Страница 196: ...Page 7 48 Workman MD MDX Chassis This page is intentionally blank Rev A...
Страница 198: ...Workman MD MDX Electrical Drawings Page 8 2 This page is intentionally blank...
Страница 199: ...Page 8 3 Electrical Schematic Workman MD Solenoid is shown de energized F3 F4 F2 F1 10A 20A 15A 30A AUTO RESETTING...
Страница 200: ...Page 8 4 Electrical Schematic Workman MDX Solenoid is shown de energized F3 F4 F2 F1 10A 20A 15A 30A AUTO RESETTING...
Страница 203: ...Rev A Page 8 7 Main Electrical Harness Drawing Workman MD and MDX Serial Number Below 280999999...
Страница 205: ...Rev A Page 8 9 Main Electrical Harness Drawing Workman MD and MDX Serial Number From 290000001 to 310000800...
Страница 207: ...Rev A Page 8 11 Main Electrical Harness Drawing Workman MD and MDX Serial Number Above 310000800...
Страница 209: ...Rev A Page 8 13 Engine Electrical Harness Workman MD WHITE BLUE BROWN BLACK GREEN BROWN WHITE BROWN...
Страница 210: ...Rev A Page 8 14 Engine Electrical Harness Workman MDX WHITE BLUE BROWN BLACK GREEN BROWN WHITE...