![Toro Reelmaster 2000 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/toro/reelmaster-2000/reelmaster-2000_operators-manual_1132156034.webp)
Inputs
Outputs
Function
Power
On
In Neutral Start On Brake Off PTO On
In Seat
Hi Temp
Backlap
Start
ETR
PTO
Start
–
–
+
O
O
–
O
O
+
+
O
Run (off unit)
–
–
O
O
O
O
O
O
O
+
O
Run (on unit)
–
O
O
–
O
–
O
O
O
+
O
Mow
–
O
O
–
–
–
O
O
O
+
+
Backlap
–
–
O
O
–
O
O
–
O
+
+
Hi-Temp
–
O
–
O
O
O
Note:
- Indicates a circuit closed to ground. - LED ON
O Indicates a circuit open to ground or de-energized - LED OFF
+ Indicates an energized circuit (clutch coil, solenoid, or start input) LED ON.
" " A Blank indicates a circuit that is not involved with the logic.
To troubleshoot, turn on the key without starting
the engine. Identify the specific function that does
not work and work across the logic chart. Inspect
the condition of each input LED’s to ensure it
matches the logic chart.
If the input LED’s are correct, check the output
LED. If the output LED is illuminated but the
device is not energized, measure available voltage at
the output device, continuity of the disconnected
device, and potential voltage on the ground circuit
(floating ground). Repairs will vary depending on
your findings.