Installation
CAUTION
Before attempting to install the ProPass - 11
HP Hydraulic Power Pack, ensure that:
•
The ProPass is located on firm level
ground.
•
The ProPass jack stand is lowered.
•
All external hydraulic and electrical power
sources are disconnected.
•
The ProPass should be prevented from
unexpected movement by blocking the
wheels at the front and the rear.
•
Use an assistant when lifting the Power
Pack assembly.
1.
Following the instructions given in the
Operator’s
Manual
for the machine. Remove the Twin
Spinner option and secure the hydraulic power
and return hoses.
Note:
ProPass models manufactured after April
2005 feature a pre-drilled chassis rear wall. If
your ProPass is pre-drilled skip instructions
2-13.
2.
Check that the ProPass chassis rear wall is
clear to mount the hydraulic tank.
Note:
Two mounting bolts must be removed
from the chassis rear wall to allow the hydraulic
tank to be mounted. Use the bolts for mounting
the tank.
3.
Remove the hydraulic tank assembly from the
crate.
4.
Support the hydraulic tank from underneath and
position the tank against the ProPass chassis
rear wall. The tank should be centered evenly
from left to right and should be positioned
vertically (
g013856
Figure 1
1.
Hydraulic tank
5.
Ensure that the inlet and outlet fittings and the
hose guide mounting bracket all fit cleanly within
the round holes in the ProPass chassis rear wall
(
).
g013857
Figure 2
1.
Holes in the chassis
6.
Ensure that the hydraulic tank is level.
7.
Using C-clamps, or similar devices, temporarily
clamp the hydraulic tank firmly in place on the
ProPass chassis rear wall.
8.
Recheck that the hydraulic tank is level.
9.
Mark the position of the hydraulic tank mounting
holes onto the ProPass chassis rear wall.
10.
Un-clamp and remove the hydraulic tank.
11.
Center punch the position of the marked holes.
12.
Drill a 7/16 inch diameter hole through the
ProPass chassis rear wall in each marked and
punched position.
3
Содержание ProPass 200