Electrical System
Battery Service
The battery is the heart of the electrical system. With
regular and proper service, battery life can be extended.
Additionally, battery and electrical component failure
can be prevented.
CAUTION
When working with batteries, use extreme cau-
tion to avoid splashing or spilling electrolyte.
Electrolyte can destroy clothing and burn skin
and eyes. Always wear safety goggles and a face
shield when working with batteries.
Electrolyte Specific Gravity
Fully charged: 1.265 corrected to 80
o
F (26.7
o
C)
Discharged: less than 1.240
Battery Specifications
BCI Group Size 28
535 CCA at 0
o
F (
−
18
o
C)
Reserve Capacity of 110 minutes at 80
o
F (27
o
C)
Dimensions (including terminal posts)
Length
10.3 inches (26.2 cm)
Width
6.8 inches (17.3 cm)
Height
9.5 inches (24.1 cm)
Removal and Installation (Fig. 21)
1. Make sure that ignition switch is in the OFF position
and that none of the LED’s on Remote Control Module
are illuminated. Loosen strap and remove battery box
cover.
2. Loosen and remove negative cable from battery. Af-
ter negative cable has been removed, loosen and re-
move positive cable.
3. Carefully remove battery from machine.
4. Install battery in reverse order making sure to con-
nect and tighten positive cable to battery before con-
necting negative cable. Tighten nuts that secure battery
cables from
10 to 15 ft
−
lb (14 to 20 N
−
m)
.
NOTE:
Before connecting the negative (ground) cable
to the battery, connect a digital multimeter (set to DC
Amps) between the negative battery post and the nega-
tive (ground) cable connector. The reading should be
less than 0.1 amp. If the reading is 0.1 amp or more, the
machine’s electrical system should be tested for short
circuits or faulty components and repaired.
5. Install battery box cover and secure with strap.
1. Strap
2. Battery box cover
3. Battery
4. Battery
box
5. Positive
cable
6. Negative
cable
7. Flange
nut
Figure 21
1
3
2
4
5
6
7
FRONT
RIGHT
Inspection, Maintenance and Testing
1. Perform the following inspections and maintenance:
A. Check battery case for cracks. Replace battery if
cracked or leaking.
B. Check battery terminals for corrosion. If corrosion
occurs at terminals, disconnect cables. Always dis-
connect negative (
−
) cable first. Clean cable clamps
and battery terminals separately. Reconnect cables
with positive (+) cable first. Coat battery posts and
cable connectors with Battery Terminal Protector
(Toro Part No. 107
−
0392) or petroleum jelly to pre-
vent corrosion.
IMPORTANT: Before cleaning the battery, tape or
block vent holes to the filler caps and make sure the
caps are on tightly.
C. Check for signs of wetness or leakage on the top
of the battery which might indicate a loose or missing
filler cap, overcharging, loose terminal post or over-
filling. Also, check battery case for dirt and oil. Clean
the battery with a solution of baking soda and water,
then rinse it with clean water.
D. Check that the cover seal is not broken away. Re-
place the battery if the seal is broken or leaking.
E. Check the electrolyte level in each cell. If the level
is below the tops of the plates in any cell, fill all cells
with
distilled water
between the minimum and max-
imum fill lines. Charge at 15 to 25 amps for 15 min-
utes to allow sufficient mixing of the electrolyte.