Cleaning the Nozzle Guides
Check and remove any grass, dirt or debris buildup
around and in between the nozzle guides (
Keep the nozzle free of debris to prevent the motor
from stalling
g021635
Figure 18
1.
Nozzle guides
Adjusting the Nozzle Belt
Service Interval:
After the first 8 hours
Every 50 hours
Adjust the belt if the belt slips when changing direction
of the nozzle.
1.
Press the belt, at the center of the longest span,
with 30 N∙m (22 lb) of force (
Note:
The belt should deflect 4.8 mm (0.19
inch).
2.
If the deflection is incorrect, proceed to the next
step. If it is correct, continue operation.
g021636
Figure 19
1.
Flange nut
3.
Depress belt here
2.
Hex nut
3.
Loosen the hex nut and tighten the flange nut to
increase the belt tension (
).
Note:
Do not over tighten.
4.
Tighten the hex nut to lock the adjustment.
15