II. Installation

Selecting an Installation Site

Install the timer with the display at eye level. If you will be using a pump, the timer must be
mounted at least 15 feet (4.5m) away from your pump start relay and pump. Do not plug the
timer into any power circuit serving a refrigerator, a pump, an air conditioner, a garage door
opener, a washer or dryer, or other high-powered equipment.

WARNING: This timer is designed for indoor installation only. Installing this timer
outdoors will void the warranty and may result in an electric shock hazard.

Mounting the timer

1.

Select an indoor location within 6 feet (1.8m) of an outlet to mount your timer. Do not use
an outlet that is controlled by an On/Of switch. Mount with display at eye level.

2.

Drive one #8 screw into wall leaving approximately 1/8" (3.2mm) exposed. Use a plastic
anchor sleeve if wall is plaster board or masonry.

3.

Mount the hanger kit to the top/back of the timer. Hang the timer on the mounting screw.

4.

Drive two additional #8 screws through the holes at the bottom of the timer case into the
wall to secure.

Note: 

To enable programming the timer prior to installation, connect a 9-volt Alkaline

battery to the battery clip at this time. Refer to “Dial Programming” on page 4 for
programming instructions.

Caution: Replace battery with the same or equivalent type. Dispose of used batteries
as recommended by the battery manufacturer.

Connect the Valves & Transformer

WARNING: To avoid an electrical shock hazard, do not plug the transformer
into the outlet until all wire connections to the timer have been completed.
The timer operates on 24 V a.c. Do not attempt to connect the timer directly to
the wall outlet. This will destroy the timer and may result in electrical shock or
fire hazard.

2

Figure 1

Содержание LawnMaster 53603

Страница 1: ...Model 53603 Owner s Manual Espa ol P 19 Fran ais P 39...

Страница 2: ...e 4 Setting Valve Run Time 5 Selecting Program Start Times 6 Canceling a Program Start Time 7 Selecting Days to Water 7 8 Run Off Positions 9 IV Manual Operation 10 11 Manual Program Cycle 10 Manual V...

Страница 3: ...n in pencil on the back of the Quick Reference Card located on the inside of the timer door The REVIEW feature can be used to review your programmed watering plan For the days you have selected in pro...

Страница 4: ...oximately 1 8 3 2mm exposed Use a plastic anchor sleeve if wall is plaster board or masonry 3 Mount the hanger kit to the top back of the timer Hang the timer on the mounting screw 4 Drive two additio...

Страница 5: ...xceed 0 25 amps maximum output holding current Also if using more than one timer do not share common wires Run a separate common wire for each timer Connecting a Pump Start Relay Note When a pump is t...

Страница 6: ...the Next button and the Minutes will flash Press the or button to change the minutes shown on the display Press the Next button and AM PM will flash Press either the or button to change AM PM 3 Month...

Страница 7: ...s 8 Set the watering time to under 1 minute or over 9 hours and 59 minutes to set the valve in OFF mode Return dial to Run position Master Valve Pump Start A master valve or pump start is sometimes us...

Страница 8: ...me position The display will flash START A1 START B1 or START C1 depending on the position of the program select switch and then show the start time programmed If there is no start time entered OFF wi...

Страница 9: ...ram details are retained Because there are no start times there will be no watering with that program This is a convenient way to stop one program without turning the dial to the OFF position in case...

Страница 10: ...the Next button to go to Skip Days 7 Press the or button to select the number of days to skip before each watering day Selecting Specific Days of the Week This option allows you to water on specific...

Страница 11: ...tion is also used to terminate any running programs whether manual or automatic allow 3 seconds to turn off For immediate shut down turn to Off and push the button 1 Set the dial to the Off position 2...

Страница 12: ...Cycle watering 4 Press the Next button until the desired starting valve is displayed That valve and all subsequent valves in the selected program will water in sequence 5 Turn the dial to Run positio...

Страница 13: ...ting Step 2 for the remaining valves 4 If using a master valve or pump press the Next button until MASTER is displayed after last valve Press the button This opens the master valve while the other val...

Страница 14: ...an 100 results in more watering 00 turns the timer to OFF Example Normal Seasonal Adjustment Program Adj Time Valve 1 Adj Time Valve 1 A 100 10 min 50 5 min B 100 10 min 170 17 min C 100 10 min 200 20...

Страница 15: ...ctive watering days By moving the program selector switch each program can be reviewed in turn You can press and hold the button to speed up the review and the button to slow down the review Erase Pro...

Страница 16: ...should be Sensor N for Off Setting Sensor Option 1 Set the dial to Special Features position 2 Press the Next button twice The display will show Sensor N 3 Press the button to activate the rain sensor...

Страница 17: ...sumes Circuit Protection Lawn Master electronics are protected from electrical disturbances such as large transient voltages and static discharge Electronic Fuse Lawn Master is protected with an elect...