Filtering the Closed-Loop Traction Circuit (GreensPro 1260)
Filtering a closed-loop hydraulic system after a major component failure
(e.g., hydraulic pump or hydraulic motor) is required to prevent debris from
transmitting throughout the system. If a filtering tool is not used to ensure the
system cleanliness, repeat failures and subsequent damage to other hydraulic
components in the system, will occur. To effectively remove the contamination
from the closed-loop traction circuit, use of a Toro bidirectional high flow hydraulic
filter and hydraulic hose kit is recommended; refer to
.
1. Park the machine on a clean, level surface with the engine off. Lower and
lock the transport wheels (drive roller off the ground).
2. Read and adhere to the information provided in
Removing and Installing the Hydraulic System Components (page 5–35)
.
3. Install a temporary hydraulic filter directly upstream of the new component as
follows:
A. If the hydraulic pump was serviced or replaced, remove the transmission
cover and disconnect the hose at the pump “A” port (
B. If the hydraulic motor was serviced or replaced, disconnect the hose
at the motor “A” port (
).
g271991
Figure 30
1.
Hydraulic pump
3.
Hydraulic pump “A” port
2.
Hydraulic motor
4.
Hydraulic motor “A” port
4. Connect the Toro high flow hydraulic filter in series between the disconnected
fitting and hose. Use the hydraulic hose kit to connect the filter to the
machine; refer to
Hydraulic Hose Kit (page 2–13)
. Ensure that the fitting and
hose connections are properly tightened.
GreensPro
™
1240/1260
Page 5–39
Hydraulic System: Service and Repairs
14211SL Rev A
Содержание GreensPro 1240
Страница 4: ...Reader Comments Page 4 GreensPro 1240 1260 14211SL Rev A...
Страница 8: ...Preface Page 8 GreensPro 1240 1260 14211SL Rev A...
Страница 14: ...Safety Safety and Instructional Decals Page 1 6 GreensPro 1240 1260 14211SL Rev A...
Страница 30: ...Specifications and Maintenance Special Tools Page 2 16 GreensPro 1240 1260 14211SL Rev A...
Страница 38: ...Troubleshooting Traction Circuit Problems GreensPro 1260 Page 3 8 GreensPro 1240 1260 14211SL Rev A...