Controls System
Maintenance
Calibrating the Levers
1.
Park the machine on a level surface, disengage
the PTO, and move the motion-control levers
outward to the P
ARK
position.
2.
In the M
AIN MENU
, scroll down to S
ERVICE
and
press the
button .
g376300
Figure 54
3.
In the S
ERVICE
menu, scroll down to L
EVER
C
ALIBRATION
and press the
button.
g376304
Figure 55
4.
If prompted, enter the PIN code.
5.
Follow the prompts on the screen. Press the
button after each step; to exit calibration, press
the Exit button.
Screen
Action
Press the
button.
Hold the left motion-control
lever in the F
ORWARD
position
and press the
button.
Screen
Action
Hold the left motion-control
lever in the R
EVERSE
position
and press the
button.
Hold the left motion-control
lever in the N
EUTRAL
position
and press the
button.
Hold the right motion-control
lever in the F
ORWARD
position
and press the
button.
Hold the right motion-control
lever in the R
EVERSE
position
and press the
button.
Hold the right motion-control
lever in the N
EUTRAL
position
and press the
button.
Press the
button.
6.
When you complete, exit, or fail calibration, shut
off then start the machine to clear the screen.
g377652
Figure 56
39