Problem
Possible Cause
Corrective Action
SPN 520193, FMI 3
1. High AC voltage error (>270VAC)
1. Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz.
SPN 524032, FMI 3
1. Charger failed to initialize
1. The charger failed to turn on properly.
Disconnect the AC input and battery
connection for 30 seconds before
retrying.
SPN 520193, FMI4
1. Low AC voltage oscillation error
1. The AC source is unstable. Could
be caused by undersized generator
or severely undersized input cables.
Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz.
SPN 524033, FMI 31
1. Re-programming failed
1. Software upgrade failure or script
operation failure. Ensure that the new
software is correct.
SPN 524035 or SPN 524042, FMI 31
1. Communication error with battery
1. Ensure that the connection of the
signal wires to the battery is secure.
SPN 524035 or SPN 524042, FMI 9
1. Communication error with battery
1. Ensure that the connection of the
signal wires to the battery is secure.
Battery-Charger Fault Codes
Problem
Possible Cause
Corrective Action
SPN 524160, FMI 31
1. Internal charger fault
1. Remove the AC connection and
battery connection for a minimum of
30 seconds and retry. If it fails again,
please contact an authorized Toro
distributor.
51