Connecting Hydraulic Control Tubing

 

Step 1 –  Route control tubing from the controller to the sprinkler location(s).

 

Note: Leave an 18" (45.7 cm) service loop of tubing at each sprinkler to facilitate movement of sprinkler and 

service operations. Refer to Hydraulic Control Systems Table for tubing run length and sprinkler elevation 

information.

Step 2 –  Flush tubing thoroughly to remove all air and debris.

Step 3 –  Remove the tube retainer and poly cap from the tubing adapter at the base of the sprinkler.

Step 4 –  Slide the tube retainer over the end of the control tubing and attach tubing to adapter. 

Step 5 –  Slide tube retainer over the adapter area to secure tubing.

  Hydraulic Control Systems Table
   

Maximum Distance 

  Type of System* 

From Controller 

Elevation Restrictions

  Normally Open  (01)  

 

Valve elevation should not exceed   

  with 3/16" Control Tubing 

500' 

25' above controller elevation or   

   

 

70' below controller elevation.

  Normally Open  (01)  

 

Valve elevation should not exceed   

  with 1/4" Control Tubing 

1000' 

25' above controller elevation or   

   

 

70' below controller elevation

*  - All hydraulic connections on Toro valves are 1/4" insert type.

  - Control line pressure must be equal to or greater than mainline pressure.

  - Control line pressure range is 40 to 150 PSI.

System Start Up

 

WARNING! Never stand or lean over the sprinkler while the irrigation system is being filled, during manual or 

automatic operation or when performing sprinkler service procedures. Direct contact with irrigation spray, a failed 

or improperly installed sprinkler connection or sprinkler components forcibly ejected upward under pressure can cause 

serious injury. 

The following is a recommended procedure that will protect system components during system start-up. The procedure 

is based on a velocity fill rate of less than 2' (.61 m) per second. See Table 3 below.

Step 1 –  Use a jockey pump only to fill the system at a velocity fill rate of less than 2' (0.61 m) per second.

 

CAUTION: Failure to comply with recommended fill rate will increase line pressure resulting in a water 

hammer effect that could damage sprinklers and piping components. See Warning above.

Step 2 –  Use quick coupler keys at all tees and greens with quick coupler valves to bleed air from the system 

lines during the filling process. For best results, do not compress air and then relieve it – bleed the air 

continuously while filling the system.

Step 3 –  After water has filled all lines and all air is removed, remove the quick coupler keys.

 

Recommended System Fill Rate

 

 

 

Pipe Size 

Flow 

Velocity 

Pipe Size 

Flow 

Velocity

  in.  cm 

GPM  LPM  ft/sec m/sec  in.  cm 

GPM  LPM  ft/sec m/sec

 1/2  1.3 

2  7.6  1.60 0.49  3  7.6  45 170.3  1.86 0.57

 

3/4 1.9  3 11.4 1.92 0.59 4 10.1  75 283.9 1.87 0.57

 1  2.5  5 18.9 1.50 0.46 6 15.2  150 

567.8 1.73 0.53

 1-1/4 3.1  10  37.9  1.86 0.57  8  20.2  250 946.3  1.70 0.52

 

1-1/2 3.8  10 37.9  1.41 0.43 10 25.4  450 

1703.0 1.97 0.60

 2  5.0  20 75.7  1.80 0.55 12 30.5  500 

1893.0 1.55 0.47

 2-1/2  6.4 

30  113.6  1.84  0.56

Содержание FLX34 Series

Страница 1: ...e 13 46 9 GPM 49 2 177 5 LPM Trajectory Selectable 15 or 25 Arc Full Circle 360 Recommended Operating Pressure 65 100 PSI 4 5 6 9 Bar Minimum Pressure 40 PSI 2 8 Bar Maximum Pressure 150 PSI 10 3 Bar...

Страница 2: ...le Positions Nozzle Set 51 Yellow Nozzle Set 52 Blue Nozzle Set 53 Brown Nozzle Set 54 Orange Nozzle Set 55 Green Nozzle Set 56 Gray Nozzle Set 57 Black Nozzle Set 58 Red Nozzle Set 59 Beige 102 0725...

Страница 3: ...pipe thread connections Use of pipe dope or other paste sealants can cause deterioration of the sprinkler body threads Tape should be applied to the male threaded fitting in compliance with the tape m...

Страница 4: ...tomatic operation or when performing sprinkler service procedures Direct contact with irrigation spray a failed or improperly installed sprinkler connection or sprinkler components forcibly ejected up...

Страница 5: ...rom the provided slot in the cap Pull the riser assembly until there is enough clearance for handling and hold onto the riser body Step 2 Remove cap screw and cap to unlock the main nozzle Step 3 Use...

Страница 6: ...tween stator and turbine Remove obstruction Drive assembly defective Replace drive assembly Nozzle base assembly defective Replace riser assembly Head sticks up Dirt in riser assembly Flush out See Fl...

Страница 7: ...pen Hydraulic Plugged controller discharge line or discharge port in pilot valve Verify by checking for discharge at discharge line when station is activated If no discharge refer to Controller Servic...

Страница 8: ...roove in body Hold onto the riser body 16 and carefully extract it from the sprinkler body CAUTION The seal retainer 12 will rapidly move upward caused by the decompressing spring 14 as it clears the...

Страница 9: ...lable use snap ring pliers to grasp rib of valve cylinder assembly and pull up and out of sprinkler body Step 3 Reinstall valve assembly using valve insertion tool P N 995 76 for FLX34 or 995 101 for...

Страница 10: ...7 Remove the retaining nut 18 and washer 17 from the pressure adjuster 11 and pull the pilot valve body assembly out of housing 16 Step 8 Remove diaphragm assembly 15 piston 14 spring 13 traveling ad...

Страница 11: ...NOTES...

Страница 12: ...NOTES 2015 The Toro Company Irrigation Division www toro com Form Number 373 0858 Rev A...

Отзывы: