background image

Pilot Valve Operation (Electric Models Only)

 

The pilot valve controls the operation of the main valve located 

in the base of the sprinkler body. The main valve is operated by 

the release of water metered through the pilot valve when it is 

activated either manually at the sprinkler or by the irrigation system 

controller.

Another important function of the pilot valve is to regulate the 

water pressure to the sprinkler nozzle. Pressure regulation 

compensates for large variations within the system and maintains 

a constant pressure for optimum sprinkler operation. The pilot 

valve is factory set to regulate one of four pressure levels: 50 psi 

(3.5 bar), 65 psi (4.6 bar), 80 psi (5.6 bar) or 100 PSI (7.0 bar).

Change the pilot valve operating pressure by loosening the thumb 

screw that secures the selector lever. Position the selector lever to 

the desired operating pressure and hand-tighten the nut.  

See Figure 5.

Troubleshooting

 

Possible equipment failures with causes and corrective action are listed below.
Sprinkler won’t rotate

  – Debris wedged between stator and turbine

    • Remove obstruction

  – Drive assembly defective

    • Replace drive assembly

  – Nozzle base assembly defective

    • Replace riser assembly
Head sticks up 

  – Dirt in riser assembly

    • Flush out. (See 

Flushing Sprinklers

)

  – Damaged or missing return spring

    • Replace

  – Damaged riser

    • Replace

Poor distribution pattern

  – Nozzle plugged with debris

    • Clean or replace nozzle

  – Nozzle orifice damaged

    • Replace nozzle

  – Low operating pressure

    • Determine why system overloaded and correct
Valve won’t close (Electric)

  – Continuous 24 VAC to sprinkler

    • Check controller for voltage source

  – Debris in Pilot Valve

    • Disassemble and remove all debris

  – Leak in pilot valve assembly

    • Replace pilot valve assembly

  – Plugged supply screen on piston

    • Clean or replace screen

  – Manual control selector on pilot valve assembly turned to “ON” position

    • Turn to “AUTO” position

  – Plunger movement restricted

    • Inspect and clean or replace

  – Valve cylinder misaligned with sprinkler body communication tube

    • Remove valve assembly and install correctly

  – Foreign object keeping valve from seating

    • Remove, clean and check valve for damage. Replace if necessary

  – Damaged piston seal or piston assembly

    • Replace valve assembly

100 PSI 

(7.0 kg/cm

2

)

80 PSI 

(5.6 kg/cm

2

)

65 PSI 

(4.6 kg/cm

2

)

50 PSI (3.5 kg/cm

2

)

Figure 5

Содержание FLX34 Series

Страница 1: ...e 13 46 9 GPM 49 2 177 5 LPM Trajectory Selectable 15 or 25 Arc Full Circle 360 Recommended Operating Pressure 65 100 PSI 4 5 6 9 Bar Minimum Pressure 40 PSI 2 8 Bar Maximum Pressure 150 PSI 10 3 Bar...

Страница 2: ...le Positions Nozzle Set 51 Yellow Nozzle Set 52 Blue Nozzle Set 53 Brown Nozzle Set 54 Orange Nozzle Set 55 Green Nozzle Set 56 Gray Nozzle Set 57 Black Nozzle Set 58 Red Nozzle Set 59 Beige 102 0725...

Страница 3: ...pipe thread connections Use of pipe dope or other paste sealants can cause deterioration of the sprinkler body threads Tape should be applied to the male threaded fitting in compliance with the tape m...

Страница 4: ...tomatic operation or when performing sprinkler service procedures Direct contact with irrigation spray a failed or improperly installed sprinkler connection or sprinkler components forcibly ejected up...

Страница 5: ...rom the provided slot in the cap Pull the riser assembly until there is enough clearance for handling and hold onto the riser body Step 2 Remove cap screw and cap to unlock the main nozzle Step 3 Use...

Страница 6: ...tween stator and turbine Remove obstruction Drive assembly defective Replace drive assembly Nozzle base assembly defective Replace riser assembly Head sticks up Dirt in riser assembly Flush out See Fl...

Страница 7: ...pen Hydraulic Plugged controller discharge line or discharge port in pilot valve Verify by checking for discharge at discharge line when station is activated If no discharge refer to Controller Servic...

Страница 8: ...roove in body Hold onto the riser body 16 and carefully extract it from the sprinkler body CAUTION The seal retainer 12 will rapidly move upward caused by the decompressing spring 14 as it clears the...

Страница 9: ...lable use snap ring pliers to grasp rib of valve cylinder assembly and pull up and out of sprinkler body Step 3 Reinstall valve assembly using valve insertion tool P N 995 76 for FLX34 or 995 101 for...

Страница 10: ...7 Remove the retaining nut 18 and washer 17 from the pressure adjuster 11 and pull the pilot valve body assembly out of housing 16 Step 8 Remove diaphragm assembly 15 piston 14 spring 13 traveling ad...

Страница 11: ...NOTES...

Страница 12: ...NOTES 2015 The Toro Company Irrigation Division www toro com Form Number 373 0858 Rev A...

Отзывы: