Connecting Input Power Wiring

WARNING! 

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION 

CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION, INSTALLATION, AND OPERATION OF 

THE PRODUCT AND THE HAZARDS INVOLVED.

AC POWER WIRING MUST BE INSTALLED AND CONNECTED BY QUALIFIED PERSONNEL ONLY. 
ALL ELECTRICAL COMPONENTS AND INSTALLATION PROCEDURES MUST COMPLY WITH ALL APPLICABLE 

LOCAL AND NATIONAL ELECTRICAL CODES. SOME CODES MAY REQUIRE A MEANS OF DISCONNECTION FROM 

THE AC POWER SOURCE, INSTALLED IN THE FIXED WIRING, HAVING A CONTACT SEPARATION OF AT LEAST 

3mm IN THE LINE AND NEUTRAL POLES. 
ENSURE THE AC POWER SOURCE IS OFF PRIOR TO SERVICING. FAILURE TO COMPLY MAY RESULT IN SERIOUS 

INJURY DUE TO ELECTRICAL SHOCK HAZARD.

1. 

Ensure the power is disconnected at the source.  

See Warning above.

2. 

Remove the terminal block cover, located below the transformer. 

3. 

Route the AC power and equipment ground wires through electrical 

conduit into the controller.

4. 

Strip wire ends to expose 3/8” (9,5mm) bare copper wire. 

5. 

Using a small flat-blade screwdriver, secure wires to the terminal 

connectors as shown in Figure 3 and as follows:

 

Line (black) to L, Neutral (white) to N, and Equipment Ground 

(green) to the Gound Lug 

6. 

Install and secure terminal block cover.

  Note: Do not apply power to the controller until all remaining 

installation procedures have been completed

Figure 3

Содержание DXi

Страница 1: ...iverside California Approx Weight 0 08 lbs OriginatingLocation Riverside Page count 8 Sheet count 4 Release Change Authorization Number 5174342 Printing instructions gray scale See subsequent pages for original PDF REVISION SHEET Rev ECM No Description ofChange Drafter Date Approved By A 5174342 Release to rev A Richard Keightley 11 8 2021 Shankara Raghuraman ...

Страница 2: ... a wall stud If installing the controller on masonry or drywall use the appropriate type screw anchors and fasteners 2 Install the screw anchors at 83 4 22 23cm A on center Caution All cabinet openings required for installation and wiring are provided Drilling or cutting through the cabinet should be avoided Metal chips and filings entering the cabinet can damage internal components 3 Install the ...

Страница 3: ...LINE AND NEUTRAL POLES ENSURE THE AC POWER SOURCE IS OFF PRIOR TO SERVICING FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY DUE TO ELECTRICAL SHOCK HAZARD 1 Ensure the power is disconnected at the source See Warning above 2 Remove the terminal block cover located below the transformer 3 Route the AC power and equipment ground wires through electrical conduit into the controller 4 Strip wire ends to...

Страница 4: ... the controller The top of the ground rod should be buried approximately 12 30 5cm below grade 2 Route a 6 AWG 13 0mm2 solid copper wire connected to the earth ground device into the controller cabinet through the access hole provided below the copper ground lug Insert and secure the copper wire to the ground lug To provide the most efficient path to earth ground route the ground wire between the ...

Страница 5: ... each wire 3 Connect the valve common wire s to terminal marked VC COM 4 Connect each valve power wire to the appropriate station number terminal See Figure 5 5 Pull lightly on each wire to confirm positive retention 6 Ensure all exposed wiring inside the controller is taped back and properly insulated 7 To release depress the small tab nearest the wire using a small blade screwdriver Output Switc...

Страница 6: ...om of the WOB One terminal is marked FLOW1 the other FLOW2 see Figure 8 Caution To prevent damage to the controller and or sensor equipment turn off power to the controller prior to connecting sensor wires Installation Notes The ALARM terminal is not used The sensor connection terminals accept 16 28 AWG 1 5mm2 0 08mm2 solid core copper wire To enable positive wire retention insulation must be remo...

Страница 7: ... switch Once a board is in Training Mode the next WOB communication it detects will cause the precode in the communication to be learned so that from that point forward the board will only listen to communications with that precode This allows multiple DXi controllers to run WOBs with the same board numbers within radio range since each WOB only listens to the precode of its master Once a board is...

Страница 8: ... switch A 10 B 11 C 12 D 13 E 14 and F 15 To test communication Send ATaaaaabb Response aaaaa bb WOB ver 0 51 or current version To read k factor Send ATaaaaabbKc where c is the flow input number 1 or 2 Response aaaaa bb Kc K setting here To set k factor Send ATaaaaabbKc ddd ddd where ddd ddd is desired k factor padded with zeros Response aaaaa bb Kc Set To read offset Send ATaaaaabbOc Response aa...

Страница 9: ...se contenu dans le présent appareil est conforme aux CNR d innovation Science et Dévellopement économique Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux condtions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est suceptible d en compromettre le fonct...

Отзывы: