7.
Open the fuel-shutoff valve; refer to
Fuel-Shut off Valve (page 22)
.
8.
Check for fuel leaks and repair if needed.
9.
Wipe up any spilled fuel.
Electrical System
Maintenance
Servicing the Battery
Service Interval:
Every 100 hours
Always keep the battery clean and fully charged. Use
a paper towel to clean the battery case. If the battery
terminals are corroded, clean them with a solution of
4 parts water and 1 part baking soda. Apply a light
coating of grease to the battery terminals to prevent
corrosion.
Voltage: 12 volts
DANGER
Do not drink electrolyte, and avoid contact
with skin, eyes or clothing. Wear safety
glasses to shield your eyes and rubber gloves
to protect your hands.
Battery electrolyte contains sulfuric acid
which is fatal if consumed and causes severe
burns.
Removing the Battery
WARNING
Battery terminals or metal tools could short
against metal machine components causing
sparks. Sparks can cause the battery gasses
to explode, resulting in personal injury.
•
When removing or installing the battery,
do not allow the battery terminals to touch
any metal parts of the machine.
•
Do not allow metal tools to short between
the battery terminals and metal parts of the
machine.
WARNING
Incorrect battery-cable routing could damage
the machine and cables causing sparks.
Sparks can cause the battery gasses to
explode, resulting in personal injury.
•
Always disconnect the negative (black)
battery cable before disconnecting the
positive (red) cable.
•
Always connect the positive (red) battery
cable before connecting the negative
(black) cable.
37