2.
To stop the auger and impeller, release the right
lever.
Important:
When you engage both the
auger/impeller lever and the traction lever,
the traction lever locks the auger/impeller
lever down, freeing your right hand. To
release both levers, simply release the left
(traction) lever.
3.
If the auger and impeller continue to rotate when
you release the auger/impeller lever, do not
operate the machine. Check the auger/impeller
cable; refer to
Auger/Impeller Cable (page 18)
and adjust it if
necessary. Otherwise, take the machine to an
Authorized Dealer for service.
WARNING
If the auger and impeller continue
to rotate when you release the
auger/impeller lever, you could seriously
injure yourself or others.
Do not operate the machine. Take it to an
Authorized Service Dealer for service.
Operating the Quick Stick®
Hold the blue trigger cap down to use the Quick Stick
to move the discharge chute and the chute deflector.
Release the trigger cap to lock the discharge chute
and chute deflector into position (
).
g001014
Figure 27
Moving the Discharge Chute
Hold the blue trigger cap down and move the Quick
Stick to the left to move the discharge chute to the
left; move the Quick Stick to the right to move the
discharge chute to the right (
g018894
Figure 28
•
If the chute does not move, refer to
Discharge-Chute Latch (page 21)
.
•
If the chute does not turn as far to the left as it
does to the right, ensure that the cable is routed
to the inside of the handles. Refer to
Upper Handle (page 5)
.
•
If the chute does not lock into place when you
release the trigger cap, refer to
Discharge-Chute Latch (page 21)
.
Moving the Chute Deflector
Hold the blue trigger cap down and move the Quick
Stick forward to lower the chute deflector; move it
rearward to raise the chute deflector (
g001016
Figure 29
13