Installing the Traction-motor Tube
1.
Align the tube nuts for the traction-motor
tube to the fittings in the traction motor and
the flow-divider manifold (
). The
shorter traction-motor tube is used on the
Groundsmaster 4500/4700 machine and the
longer traction-motor tube is used on the
Reelmaster 7000 machine.
g312775
Figure 15
Groundsmaster 4500/4700 Shown
1.
Traction motor
4.
Traction-motor tube
(flow-divider fitting)
2.
T-fitting
5.
Flow-divider manifold
3.
Traction-motor tube
(traction-motor fitting)
6.
Forward
2.
Thread the tube nuts for the traction-motor tube
onto the fittings in the traction motor and the
flow-divider manifold, and tighten the nuts to 116
to 142 N-m (85 to 105 ft-lb).
Installing the Tank Hose
Important:
This procedure is necessary if you
are going to install the 4WD switch.
1.
Remove the temporary cap from the bulkhead
fitting and thread the angled end of the tank
hose onto the bulkhead fitting.
g312776
Figure 16
Bottom View
1.
Hydraulic tank fitting
3.
Bulkhead fitting
2.
Tank hose
Note:
Ensure clearance for the coils by facing
the angled end and hose out toward the right
side of the machine, perpendicular to the frame.
2.
Remove the temporary cap from the fitting on
the hydraulic fluid tank, and thread the straight
end of the tank hose onto the fitting.
3.
Tighten the forward, straight end attached to the
tank to 50 to 64 N-m (37 to 47 ft-lb).
4.
Tighten the angled end attached to the bulkhead
to 81 to 100 N-m (60 to 74 ft-lb).