Air filter icon:
the air filter icon is green unless the
filter is plugged then the indicator is red.
Hydraulic-fluid filter icon:
the hydraulic-fluid filter
icon is green unless the filter is plugged then the
indicator is red.
Engine droop icon:
select the allowable engine
droop of 80, 90, or 100%. The droop value is the
lowest point below low-load speed (rpm) (under 75
percent load) that the engine may decrease before
the drive to the rotary head is decreased to maintain
the lowest value. Push the up and down arrows to
select the droop value.
Cam Arm I/O Screen
To access this screen push button 3 on the I/O screen.
Use this screen to adjust the cam and pipe loader
calibration options.
g213146
Figure 65
1.
Push button 3 to calibrate.
1.
Push button 3 to toggle the calibration on and off.
2.
Push the up and down buttons on the display
to select the load position and the pipe-row
position.
3.
Push the OK button 2 times on the desired
position to save the calibration.
The 2 voltages on the bottom indicate the loader
arm and cam actual voltage from the sensors. The
voltages range from 1.0 to 4.0 V. Any voltage higher
or lower indicates either sensor failure or incorrect
calibration.
Joystick Help Screens
To access these screens push button 4 on the I/O
screen.
These screens show the function of each joystick
button.
Push the up and down arrows to scroll through the
screens.
g287762
Figure 66
4-Button Joysticks
g287757
Figure 67
g287758
Figure 68
17