g005080
Figure 6
3.
Carefully fill each cell with electrolyte until the
plates are covered with about 6 mm (1/4 inch)
of fluid (
).
g032705
Figure 7
1.
Electrolyte
4.
Allow approximately 20 to 30 minutes for the
electrolyte to soak into the plates. Fill as
necessary to bring the electrolyte to within about
6 mm (1/4 inch) of the bottom of the fill well
(
).
5.
Connect a 2 to 4 A battery charger to the battery
posts. Charge the battery for at least 2 hours at
4 A or for at least 4 hours at 2 A until the specific
gravity is 1.250 or higher and the temperature is
at least 16°C (60°F) with all cells gassing freely.
WARNING
Charging the battery produces gasses
that can explode.
Never smoke near the battery and keep
sparks and flames away from the battery.
Important:
If you do not charge the battery
for at least the time specified above, you may
reduce the life of the battery.
6.
When the battery is charged, disconnect the
charger from the electrical outlet and battery
posts.
Note:
After the battery has been activated,
add only distilled water to replace normal loss,
although maintenance-free batteries should not
require water under normal operating conditions.
Important:
Failure to correctly activate the
battery may result in battery gassing and/or
premature battery failure.
7.
Install the vent caps.
8.
Place the battery on the battery tray and secure
it with the battery clamp and fasteners removed
previously.
9.
Install the positive cable (red) to the positive (+)
terminal and then the negative cable (black)
to the negative (–) terminal of the battery and
secure them with the bolts and nuts (
).
Slide the rubber boot over the positive terminal
to prevent a possible short from occurring.
WARNING
Incorrect battery cable routing could damage
the tractor and cables, causing sparks.
Sparks can cause the battery gasses to
explode, resulting in personal injury.
•
Always disconnect the negative (black)
battery cable before disconnecting the
positive (red) cable.
•
Always connect the positive (red) battery
cable before connecting the negative
(black) cable.
g005098
Figure 8
1.
Negative (-)
2.
Positive (+)
12