![tornos SAS 16.6 Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/tornos/sas-16-6/sas-16-6_instruction-manual_1130778038.webp)
300801_en - 12/12
2. Installation - Instruction manual - SAS 16.6
2-12
2.7.1.3. Connection via an autotransformer.
Fig. 7
Starting condition
- Machine in place and stabilised.
Step
Key
Action / Observation
1.
Disconnect the autotransformer (3) from the local mains electrical
installation (4).
• This is to be carried out by a qualified and authorised member of
staff.
2.
Connect the autotransformer mains cable (3) on the machine
terminal block (2).
• Minimum cable cross-section 6 mm²
• See
3.
Reconnect the autotransformer (3) to the local mains.
4.
Turn the main switch (1) "ON".
5.
Check the rotating field.
6.
Check the voltage at the socket.
• 220-240 V (Europe).
• 100-110 V (US).
(2)
(3)
(1)