![Tormax Automatic iMotion 2202 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/tormax-automatic/imotion-2202/imotion-2202_instructions-for-use-manual_1130471009.webp)
Instructions for use T-1321 e
9
3 System Overview
T1321_4e
3c
3a
3a
HK
Drive side
Opposite drive side
NK
NK
5a, 7a
3d
3c
3d
3b
3b
1
4a
4c
8b
7c
7b
6a
6b
2a 4d
4b
8c
7d
7d
2a
8a
2b
1 Drive
Cladding
Motor unit
MCU32 control system with monitoring system, power limitation and perma-
nent diagnosis
Guide system with noise-absorbent guide rail
2 Drive accessories
£
Lock with
a)
£
internal manual activation
£
in the cladding
£
on the wall
b)
£
external manual activation
£
Emergency power supply via the battery unit
£
Mechanical emergency opening
3 Door leaves
a) Moving leaves with main closing edge (HK) and secondary closing edge (NK)
b) Moving leaves with floor guide *
c)
£
Side part
*
d)
£
Protection leaves as protection for the secondary closing edge
*
4 Operating controls
a)
£
iMotion user interface with 6 operating modes and fault display
b)
£
Operating mode switch with 3 positions.
c)
£
Lock for the user interface
d)
£
Remote control of operating modes
5 Activators drive side
a) With automatic activation
b) With manual activation
£
Radar with/without direction recognition *
£
Push button *
£
IR motion detector *
£
Contact-free button *
6 Activators opposite
drive side
a) With automatic activation
b) With manual activation
£
Radar with/without direction recognition *
£
Key switch
£
IR motion detector *
£
Card reader *
£
Remote control *
7 Safety sensors
a)
£
Presence sensor *: main closing edge protection
b)
£
Presence sensor, external *: main closing edge protection
c)
£
Safety beams *
d)
£
Presence sensors *: secondary closing edge protection
8 Emergency systems
a)
£
Power switch * / fuse *
b)
£
Emergency on/off switch *
c)
£
Fire alarm system *
9 Output message
£
Bell / gong *
£
Light / ventilation *
£
Door locked
£
Door status ………………
£
Depending on the system’s equipment.
* Not offered by the manufacturer.
The company installing the system must select and install suitable components in accordance with the prod-
uct standard EN16005 / DIN18650.