10
SECTION III
OPERATION
3-1
General
All TORC, LLC. Torque Machines are supplied completely assembled and ready for use. A TORC Hydraulic
Power Pack (for use with your TORC machine) is recommended to provide the speed, pressure, and
portability that makes your TORC System efficient and accurate.
The System accuracy of your TORC tool is +/- 3%, based upon manufacturer’s specifications. This
accuracy may be certified through calibration by TORC or any other qualified calibration facility whose
program is traceable to the National Institute of Standards and Technology (N.I.S.T.).
Using a calibrated gauge enhances the accuracy of your TORC System.
3-2
Connecting the System
The wrench head and power pack are connected by a 10,000 PSI operating pressure (40,000 PSI burst)
twinline hose assembly. Each end of the hose will have one male and one female connector to assure proper
interconnection between pump and wrench heads.
IMPORTANT: To avoid tool malfunction. Do not reverse connectors.
Connect the twinline hose to the uni-swivel as shown below:
Insure the connectors are fully engaged and screwed snugly and completely together.