VIII. Maintenance of “TMR140 Series”
1. Maintenance Items and Maintenance Frequency
Please perform strictly the following items to maintain “TMR140 Series" in good
condition.
(1)
Clean the air diffusers (everyday)
(2)
Chemical cleaning of the element (every 6 months or when the trans-membrane
pressure has risen by 5 kPa or more from its initial operating level at the same
permeated water flow rate, whichever comes first).
(3)
Replace connection tubes (once in 3 years, or when deteriorated)
(4) Replace element fixing gaskets (once in 3 years or when deteriorated, whichever
comes first).
(5)
Replace elements (when the specified treatment flow rate is not gained even after
chemical cleaning or when deteriorated, whichever comes first).
*
Be sure to use the specified types of the replacement parts,
*
Please contact us for the detailed specifications and the procurement routes
for replacement parts.
*
Insert the tube securely into the foot of the nozzle when replacement.
*
Don't apply excess force to the element and manifold nozzles to prevent
damage when replacing permeate tubes or elements.