AIRE-064-1-4
23
4. Storage Products
Please store "TMR140 Series" indoors under lower than 40 degree C of the temperature,
keep it horizontal and avoid direct sunlight to prevent the membrane from deterioration.
Throughout the entire process of installation work from transportation to operation startup,
please take adequate measures to protect the elements and other components from damage.
Especially please protect them from sparks caused in welding, fusion cutting or grinding,
using fireproof sheets or other protective measures.
If
“TMR140 Series”
is to be stored outdoors unavoidably during construction period, please
minimize the period of outdoor storage, and also comply with the following requirements:
(1) Maintain the temperature below 40 degree C.
(2) Prevent from freezing.
(3) Prevent from getting wet.
(4) Prevent from immersed in the water.
(5) Avoid direct sunlight.
Please do not leave "TMR140 Series" for hours in the place where
the temperature is higher than 40 degree C or in the place exposed
to direct sunlight.
Especially ABS supporting panel may be deteriorated with direct
sunlight, ultraviolet ray.
Protect “TMR140 Series” from freezing.
Take adequate measures to protect “TMR140 Series” from sparks
caused in welding, fusion cutting or grinding.
Protect the element from damages. Don't put any heavy objects on
the module. Protect it from collision with other object.
Be careful not to damage the rubber parts of air diffusers and
element fixing brackets.
5. Installation
Products
Please install “TMR140 Series” in the membrane submerged tank with the following steps.
Please make sure beforehand that all necessary works in the membrane submerged tank
are completed and all waste is removed from the tank, such as concrete clusters, scrapes
and mill ends.
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
!