2. Safety Instruction for Filtration Operation
Flush all the piping out with clean water and make sure no debris is remaining in
the piping prior to connecting the modules.
Confirm that the preservative chemical in the modules is completely drained out
before starting the filtration operation. The preservative chemical is harmful to
humans.
Flush the modules at low pressure, filling from the bottom, and vent to remove any
air from the modules. Air left in the modules may cause water hammer and may
result in damage to the membrane.
Prior to use, make certain modules are flushed. Filtrate should be drained unless it
meets the required quality.
Protect modules from direct sunlight and ultraviolet light. Ultraviolet light can
degrade module housings and membranes.
Constantly monitor filtrate quality such as turbidity and/or the number of particles
during filtration, and stop the operation if abnormal water quality is detected.
!
!