TORAY UF
Instruction Manual
06-G-MB2-HFUG-B2315AN-220930
17 of 35
V. Installation
The standard procedure to install membrane modules is described below.
1. Unpack membrane module(s) from a wooden box or corrugated box.
Be sure to wear protective gloves to avoid injury of
hands by packing box of the modules.
2. Remove a plugging plate from each nozzle of the module.
3. Drain out the preservative solution from the module.
Wear rubber gloves and safety glasses when draining
the preservative chemical. Note that the preserving
chemical is sodium hypochlorite solution (Max. 200 mg/L
as Cl
2
). If this solution splashes onto your skin, wash the
affected part with running water. If the solution gets in
your eyes or mouth, wash the affected part with enough
amounts of running water for over 15 minutes and see
the doctor immediately.
4. Put the module vertically on a piping or a pedestal in the module rack. Fix the module
upright with the connections and/or a support belt (see Fig. 2). When installing a pedestal,
decide its size and location considering the shapes and overall lengths of Type A, B and
C.