background image

Verdin Development Board Errata 

 

Toradex AG  lEbenaustrasse 10  l  6048 Horw  l  Switzerland  l  +41 41 500 48 00  l  

www.toradex.com

 l  

[email protected] 

 

Page 7 | 19 

 

Errata #4:  

HAR-3935 – CTRL_FORCE_OFF_MOCI# is pulled-up to wrong voltage 
rail 

Affected Version:  

Verdin Development Board V1.0B 

Fixed in:  

 

Verdin Development Board V1.1A

 

4.1 

Customer Impact 

The main power gets killed when the CTRL_PWR_EN_MOCI# goes low and the +V1.8_SW rail is 
turned off. This means the main power is killed during a reset cycle, and the power-down 
sequence is not graceful.  

4.2 

Description 

According to the Verdin specifications, the CTRL_FORCE_OFF_MOCI# is an open-drain output of 
the module, which is 5V tolerant and requires a pull-up resistor on the carrier board. On the 
Verdin Development Board V1.0B, the CTRL_FORCE_OFF_MOCI# is pulled up to the +V1.8_SW 

rail. Unfortunately, this rail is switched by the CTRL_PWR_EN_MOCI# signal. During a reset cycle 
(software or button initiated), the CTRL_PWR_EN_MOCI# signal can go low for power cycling the 
peripherals on the carrier board. This is also disabling the +V1.8_SW, which means the 
CTRL_FORCE_OFF_MOCI# goes low and triggers the kill input of IC16. The IC16 then kills the 
main power of the module. This means resetting the module can cause an unintentional power-off 
of the system.  
 
During a regular power-down cycle, the CTRL_FORCE_OFF_MOCI# signal is supposed to go low 
as the last step after all the module and carrier board peripheral rails are shut down in the correct 

order. Due to the incorrectly pulled up CTRL_FORCE_OFF_MOCI# signal, the main power gets 
killed in a too early state. This means the power rails are not shut down in the intended graceful 
sequence. Even with this non-graceful shutdown, damages on the module or carrier board are not 
expected.  

4.3 

Workaround 

Removing R80 disables the CTRL_FORCE_OFF_MOCI# signal on the Verdin Development Board. 
However, this disables the "kill-feature" entirely. Therefore, the supplies are not turned off after a 
shutdown, which prevents the system from being turned on by using the power button. For turning 
on the system, either power cycle the whole board or turn off the main 3.3V rail on the carrier 

board by pressing the power button for >3s. Besides this inconvenience, the modification is 
compatible with all Verdin module versions.  
 
An alternate workaround is removing R95 and adding a 100k

 pull-up resistor from 

CTRL_FORCE_OFF_MOCI# to +V5_STB. This makes the circuit fully compatible with the new 
Verdin modules. The kill-feature would work with this modification as intended with the new 
Verdin modules. However, for the older Verdin iMX8M Mini V1.0B module, the 
CTRL_FORCE_OFF_MOCI# is not 5V tolerant, and the CTRL_FORCE_OFF_MOCI# signal gets also 
asserted during the reset cycle. After the modification, the development board is no longer 
compatible with the Verdin iMX8M Mini V1.0B. Read Errata #13 and Errata #5 of the Verdin 

iMX8M Mini V1.0B module for more information. The following picture shows one potential 
implementation of the alternate workaround patch: 
 

Содержание Verdin Development Board

Страница 1: ...Verdin Development Board Errata Document...

Страница 2: ...90 Initial Release 2020 03 31 Rev 0 91 Errata 2 Title and content updated 2020 04 14 Rev 0 92 Minor cosmetic improvements 2020 09 10 Rev 0 93 Fix versions updated Errata 4 Added 2021 02 08 Rev 0 94 E...

Страница 3: ...lled up to wrong voltage rail 7 Errata 5 HAR 6600 Ethernet PHY address strapping resistor for configuring PHYAD2 missing 9 Errata 6 HAR 7206 Series capacitor values are too small for the audio codec s...

Страница 4: ...ct This error might create confusion while using this product feature 1 2 Description The position of LED21 LED22 LED23 LED24 in the general purpose LEDs and Switches area is not consistent with the o...

Страница 5: ...y at HS400 mode due to signal integrity issues Regular SD cards are working fine as expected 2 2 Description SDIO interface is failing when SDIO evaluation kits are used in HS400 mode By default the s...

Страница 6: ...Fixed in Verdin Development Board V1 1A 3 1 Customer Impact The absence of a pull up resistor may lead to an ambiguous signal state 3 2 Description The WAKE1_MICO signal is an open drain signal driven...

Страница 7: ...module and carrier board peripheral rails are shut down in the correct order Due to the incorrectly pulled up CTRL_FORCE_OFF_MOCI signal the main power gets killed in a too early state This means the...

Страница 8: ...a Toradex AG lEbenaustrasse 10 l 6048 Horw l Switzerland l 41 41 500 48 00 l www toradex com l support toradex com Page 8 19 Figure 1 Verdin Development Board CTRL_FORCE_OFF_MOCI pull up patch Top Sid...

Страница 9: ...ts of the PHY address are strapped by the PHYAD0 PHYAD1 and PHYAD2 pin PHYAD0 and PHYAD1 are located on the LED output signals which are strapped correctly PHYAD2 is located on the RXC pin of the PHY...

Страница 10: ...ase one end of each speaker s coil is connected to the common ground pin GND the other ends are connected to the audio codec IC through the capacitors C182 or C183 respectively The capacitors C182 1uF...

Страница 11: ...x AG lEbenaustrasse 10 l 6048 Horw l Switzerland l 41 41 500 48 00 l www toradex com l support toradex com Page 11 19 Figure 3 Verdin Development Board connection of the external speakers in a stereo...

Страница 12: ...CSI_1_MCLK signal pin 12 of X47 and if it requires this signal to be at 3 3V level then the current voltage level of the signal won t be compatible with the camera 7 2 Description On the MIPI CSI 2 in...

Страница 13: ...2 used to indicate the link and activity statuses on the bus These LEDs are available on pin 235 and 237 of the module edge connector respectively ETH_1_LED_1 pin 235 is intended to indicate the activ...

Страница 14: ...Module specific pin MSP_8 104 of the SoM edge connector Module specific pins feature stitching capacitors for providing current return paths for cases when those pins are being used for accommodating...

Страница 15: ...oradex com Page 15 19 Figure 4 Location of C250 and C313 top side If the carrier board is connected to a Verdin iMX8M Plus V1 0B another stitching capacitor needs to be removed from the SoM For more i...

Страница 16: ...nd R138 connected to the pins 26 and 24 of the audio codec IC28 affect the functionality of the device s internal multiplexers and signal amplifiers The analog input pins of the audio codec shift the...

Страница 17: ...en the pull up voltage at the gates of the transistor level shifters the DBG_PWR_BTN DBG_FORCE_OFF DBG_RESET DBG_RECOVERY and the FTDI_JTAG_TRST signals can get unintentionally triggered when connecti...

Страница 18: ...rd Errata Toradex AG lEbenaustrasse 10 l 6048 Horw l Switzerland l 41 41 500 48 00 l www toradex com l support toradex com Page 18 19 Figure 6 Location of R165 R168 R172 and R175 top side Figure 7 Loc...

Страница 19: ...content in this document are provided as is with no warranties of any kind and are for informational purposes only Data and information have been carefully checked and are believed to be accurate how...

Отзывы: