泰智科技
Shenzhen Topwisdom Technology Co., Ltd
18
sensor input
4
IN-4
Y upper limit, axis movement to the max coordinate limit sensor
input
5
IN-5
Y origin limit, axis movement to the minimum coordinate(0)limit
sensor input
6
XGND
External 5V power source grounding (output)
Z, U axis limit interface J7
Pin
Definition
1
EX 5V
External 5V power source positive (output)
2
IN-7
Z origin limit, axis movement to the minimum coordinate(0)limit
sensor input
3
IN-8
U origin limit, axis movement to the minimum coordinate(0)limit
sensor input
4
IN-9
Opening protection signal input
5
IN-10
Foot switch signal input
6
XGND
External 5V power source grounding (output)
The general input interface
Input interface J4
Pin
Definition
1
EX 5V
External 5V power source positive (output))
2
IN-11
U axis upper limit switch input
3
IN-12
U axis lower limit switch input
4
IN-13
V origin limit, axis movement to the minimum coordinate(0)limit
sensor input
5
XGND
External 5V power source grounding (output)
When using the single laser control, the water protection signal of another laser must
be shorted with XGND, otherwise, the machine don’t work.
Содержание TL-403
Страница 14: ...Shenzhen Topwisdom Technology Co Ltd 8 Fig 2 5...
Страница 36: ...Shenzhen Topwisdom Technology Co Ltd 30 Fig 3 21 Double click the System show as Fig 3 22 Fig 3 22...
Страница 37: ...Shenzhen Topwisdom Technology Co Ltd 31 Fig 3 23 Click the device management Fig 3 24 The assigned COM port...
Страница 41: ...Shenzhen Topwisdom Technology Co Ltd 35 Fig 3 30 Double click TCP IP setting Fig 3 31...