TOPVERT L1 Series
E-
21
16: Torque adjust
Pr3-03 AI1 analog Input bias
-10.00
~
10.00V
0.00
Pr3-04 AI1 analog Input gain
-500.0
~
+500.0%
100.0
Pr3-05 AI1 analog Input bias mode
0: Zero bias
0
1: Value lower than bias = bias
2: Value higher than bias = bias
3: The absolute value of the bias voltage while
serving as the center
Group 4: Multi-Step Speed and Process Logic Control operation parameters
Parame
ters
Functions
Settings
Factory
Setting
User
Pr4-00
The 1st step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-01
The 2nd step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-02
The 3rd step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-03
The 4th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-04
The 5th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-05
The 6th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-06
The 7th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-07
The 8th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-08
The 9th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-09
The 10th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-10
The 11th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-11
The 12th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-12
The 13th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-13
The 14th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-14
The 15th step speed of PLC Run
or MSS Run
0.00
~
600.00 Hz
0.00
Pr4-15
The duration of master speed
0.0
~
65500 Sec
0.0
Pr4-16
The 1st step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-17
The 2nd step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-18
The 3rd Step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-19
The 4th Step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-20
The 5th Step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-21
The 6th Step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-22
The 7th Step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-23
The 8th Step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0
Pr4-24
The 9th Step duration of PLC
Run or MSS Run
0.0
~
65500 Sec
0.0