22
-
30 pF maximum between conductors.
Ethernet
4.1.3
The Ethernet controller on revision 2.0 CPU boards uses HP Auto-MDIX technology. By
automatically detecting the signaling on the connected device, the transceiver will configure the
port settings automatically. Thus, the choice of a straight through or cross over cable no longer
has to be made
—either will work.
Ethernet is available on MultiLoad II/RCUII with revision 2.0 or higher CPU boards.
Wire used must meet the following characteristics:
-
Ethernet wiring standard T568B - Cat5 cable (or greater).
Communication Connection Wiring
4.2
This section describes the wiring connections for each of the communication ports in order to function
for a specifc communication protocol.
FCM I / FCM II Communications (MultiLoad II Product Only) - COM 0 –Port – RS485
4.2.1
FCM I, FCM II and PCM modules communicate with the MultiLoad II using the COM0. This is a
dedicated communication line.
The FCMII modules linked to a specific MultiLoad II are all on a RS-485 bus connected this COM 0
port.
The TD and RD pairs are swapped at the MultiLoad II.
If an internal I/O board is installed, this board is already connected to COM 0 and is addressed as
FCM #0.
All FCMs must be uniquely addressed.
Содержание MultiLoad II DIV-2
Страница 1: ...MultiLoad II RCU II DIVISION 2 DIV2 Installation Guide Part 6074...
Страница 7: ...Hardware Revision 80 9 1 Manual Revision 81 9 2...
Страница 18: ...9 2 1 2 2 Back View Figure 2 3 Unit Outline Drawing Back View RCUII ML II Div 2 MOUNTING TEMPLATE...
Страница 20: ...11 2 1 2 4 Side View Figure 2 6 Unit Outline Drawing Side View...
Страница 25: ...16 Figure 3 1 Suggested Mounting Position Figure 3 2 Screen Visible Area...
Страница 59: ...50 Typical 1 Meter Application Wiring Example IP E Drawing Electrical Wiring Schedule 5 4 14...
Страница 64: ...55...
Страница 73: ...64...
Страница 88: ...79 Chapter8 HardwareRevisionHistory Compatibility Chapter 8...