7.1
TROUBLESHOOTING
6.3
DEMOLITION
%
Program selection knob (mod. KC1);
%
Electromechanical Electric-lock;
%
Miniaturized photocells (mod. F1 and mod F2);
%
Ultra flat wall button;
%
Antipanic door opener (simple or complete);
%
System for glass door;
Should arise the need to use accessories other than those mentioned, the installer can apply directly to our technical
support service.
IT
USO E FUNZIONAMENTO
5
IT
TROUBLESHOOTING
7
INSTRUCTIONS FOR INSTALLATION AND USE
EN
T120-T240
Demolition of the automation must be handled in respect of the legislation in force on the subject of environmental
safeguards. This means that the parts of the automation must be separated by type of material.
The emergency battery should be removed from the device before disposal (remember to cut off the power supply); it
must be disposed of safely because it contains hazardous substances.
When the green led DS1 lights up the
electronic control board does not switch on
Check the mains voltage 230V, the contacts on the electronic
control circuit, transformer voltage, fuse.
When the yellow led DS3 lights up the
electronic control board blinks and the door
does not move
Check the 24V supply voltage of the peripherals, the sensors,
photocell contacts and NO-NC logic, safety devices, antipanic
device, door opening and lateral guards. After amending the input
logic of the safety devices, perform a reset.
After opening, the door stays in the open
position
Check the photocells and their contacts,
and their
the sensors,
contacts, check for possible friction in the glide, battery
discharged
During closure, the door reopens by itself
repeatedly
During opening or closing the door is
excessively noisy
With functions set by the switch the door does
not open
The door does not function and the display of
the control circuit shows symbols or letters
Check the position or sensitivity of the sensors, alignment of the
photocells, possible friction in the glide
Check that there are no scraps on the glide rail, check carriage
alignment, glide wheels, runners on the floor.
Check the sensors contacts, electromechanical block, switch
contacts
Check the malfunction signal consulting the list of messages and
alarms
PROBLEM
REMEDY
57
Содержание T120
Страница 2: ......
Страница 21: ...1 2 Fig 23 Fig 22 2 3 1 4 5 4 180 INSTRUCTIONS FOR INSTALLATION AND USE EN T120 T240 Fig 24 VE 21 ...
Страница 27: ...Fig 34 Fig 35 Fig 36 30 30 INSTRUCTIONS FOR INSTALLATION AND USE EN T120 T240 27 ...
Страница 59: ......