DIGITAL PROGRAM SWITCH
TOTAL ENTRY/EXIT
- The external/internal sensors are enabled and the automatic opening of the door is total.
PARTIAL ENTRY/EXIT
- The external/internal sensors are enabled and the automatic opening of the door is
reduced.
OPEN
- The door opens automatically from whatever position it is in, and remains blocked with the door open.
CLOSED
- The door closes automatically from whatever position it is and all the sensors are disabled.
ENTER ONLY
- The internal exit sensor is disabled and the external entry sensor is enabled.
EXIT ONLY
- The external entry sensor is disabled and the internal exit sensor is enabled .
LIST OF MODES
The digital switch model DS2, serves to select different operating modes of
the door using the keys. The program function selected is signaled on the luminous display.
INTERBLOCK
- You enable the interlock function of a pair of door. The interlock provides the
Combined operation of two doors operated by a single switch that can be set in DS2: single output, single entry and
automatic. Here's an example:
Door 1 open -> door 2 does not open as long as the door 1 is open
Door 2 opening -> door 1 does not open as long as the door 2 is open.
To enable interlock enter the menu PARAMETERS -> INTERLOCK -> YES.
This will allow you to scroll the menu upward.
This allows you to increase the value of the function selected
This allows you to confirm the function selected and change mode .
In case of error, if you press this key for 3sec, it will reset to zero
(near).
This allows you to scroll the menu downward. Hold for 4 sec to enter
the menu
This allows you to decrease the value of the function selected and
return to the previous menu