EN
INSTRUCTIONS FOR INSTALLATION AND USE
DUEVILLE
43
5.6
PROGRAMMING PARAMETERS ON THE DUEVILLE
ENTER
DOWN
Code
Description
Parameters set from digital switch
Opening speed adjustment at 45cm/s and closure at 25cm/s
Opening/closing speed increase at 45cm/s
Opening speed increase at 65cm/s and closure at 35cm/s
Presence of electric lock ( without dot=electric lock not present )
Presence of battery ( without dot=battery present)
Partial opening (without dot=disabled =70%, with dot=enabled =40%)
Seal on closure ( without dot=disabled=0; with dot=enabled=Level 2 )
Tautomatic and partial reclosing time ( without dot=disabled=5 ; with dot=enabled=0 )
It is possible to enter the basic parameters using the 7 segment display (
see fig.8
) and the
<ENTER> and <DOWN> keys.
Press and hold <ENTER> for 5 sec to enter the configuration menu.
The presence on the display of a dot next to a parameter code indicates that the function is enabled.
Press <DOWN> to pass from a parameter to another, press <ENTER> to enable/disable the
function.
WITHOUT DOT-monitored sensors (with test) type Optex OA-Axist T or
Hotron HR100_CT
WITH DOT-NC not monitored sensors (without test connection)
Safety logic:
Non utilizzare
(Allows the use of "Wings free", if the automation board is set up for the "Wings free", function)
Changes the operating mode of the buttons for TS1, TS2 and MS1 for ”WINGS FREE”
operation mode ( with dot=enabled ; without dot=disabled )
If the
MS1
program selection knob is available, selecting “Enter only” , “Wings Free” is activated.
If the
TS2
remote control is available, pressing the button “Enter only” ,“Wings Free” is activated.
If the
TS1
remote control is available, pressing the button “Open” , “Wings Free” operation mode is activated.
Pressing the button “Open” for more than 10 seconds, the “Open” operation mode activates.
Description of behavior / y parameter = with dot
1. Press the “DOWN” key and hold for 5 seconds. The sequence of characters “Radio” appears on the 7-segment display.
2. If you have the Topp remote control
TS2
press the smooth side of the first key (open function).
If the Topp
TS1 4-
channel remote control is available, press the second key (Close Function).
To deactivate all radio control devices:
To program the radio control devices (up to 8):
1. Press the “DOWN” key and hold for 5 seconds, then release it. The sequence of characters “Radio” appears on the 7-
segment display.
2. Press the “DOWN” key and hold for a further 5 seconds, all remote controls connected to the electronic board will be
deactivated.
To confirm that all programmed remote controls have been deactivated, the sequence of characters "Radio" will no longer
be displayed.
To confirm that the remote control has been memorized, the "Radio" character sequence will no longer be displayed.
Содержание DUEVILLE
Страница 2: ......
Страница 52: ...52 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Страница 53: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 53 ...
Страница 54: ...54 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Страница 55: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 55 ...
Страница 56: ...56 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Страница 57: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 57 ...
Страница 58: ...58 EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE ...
Страница 59: ...EN INSTRUCTIONS FOR INSTALLATION AND USE DUEVILLE 59 ...