![Topcon GTS-821A, GTS-822A, GTS-823A, GTS-825A Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/topcon/gts-821a-gts-822a-gts-823a-gts-825a/gts-821a-gts-822a-gts-823a-gts-825a_instruction-manual_1128642080.webp)
5-22
5 PROGRAM MODES
5
Collimate the left side of the column (P2) and
press the [F6](SET) key.
After the measurement, angle measuring
display of the right side (P3) will be shown.
Collimate
P2
[F6]
6
Collimate the right side of the column (P3)
and press the [F6](SET) key.
After the measurement, the distance between
the instrument and center of the column (P0)
will be calculated and displayed.
Collimate
P3
[F6]
7
To show the slope distance of point P0, press
the [F2](SD) key.
[F2]
8
To show the coordinates, press the [F3](NEZ)
key. *1)
[F3]
*1) To repeat the offset measurement, press the [F1](NEXT) key. The display will return to step 4.
COLUMN OFFSET
Right
HR : 95
°30'40"
SET
COLUMN OFFSET
HR: 90°30'40"
HD: 10.321 m
VD: 0.886 m
NEXT SD NEZ REC
COLUMN OFFSET
V : 85°30'30"
HR: 90°30'40"
SD: 10.999 m
NEXT HD NEZ REC
COLUMN OFFSET
N : 17.321 m
E : 10.962 m
Z : 0.886 m
NEXT SD HD REC
Содержание GTS-821A, GTS-822A, GTS-823A, GTS-825A
Страница 1: ...INSTRUCTION MANUAL AUTO TRACKING TOTAL STATION GTS 820A SERIES GTS 821A GTS 822A GTS 823A GTS 825A...
Страница 2: ......
Страница 120: ...11 4 11 SETTING ATMOSPHERIC CORRECTION...
Страница 121: ...11 5 11 SETTING ATMOSPHERIC CORRECTION...
Страница 143: ......