23
Adjusting Mode
Adjust the instrument by the following steps.
1
Set the instrument at the center between staff A and B.
Center the bubble of the circular level with the three leveling screws.
2
While pressing the [HDif] key, press power switch to set the indicator
adjustment mode.
3
Collimate the staff A and push the [Meas] key. (step1)
4
Collimate the staff B and push the [Meas] key. (step2)
5
Set the instrument at the position that is approximately 3m apart from
the staff A.Center the bubble of the circular level again with the three
leveling screws.
STAFF A
STAFF B
Approximately
Approximately
15m
15m
STAFF A
STAFF B
Approximately 3m
Approximately 27m