8
TMR3610 Operators Manual
D4023-EN
4.0 TECHNICAL SPECIFICATIONS
SIZE
10.25” long x 8.0” high x 4” wide (260mm x 190mm x 105mm)
WEIGHT
4.5 lbs. (2.04 Kg)
HELP MESSAGES
Context sensitive help messages in 10 languages, Long messages are scrolled
LOAD CELL EXCITATION
8 volts D.C. Nominal, Capable of driving ten 350 Ohms transducers, Short circuit
proof
AUTO TEMPERATURE
COMPENSATION
Of internal circuitry for high accuracy weighing measurements
LOAD CELL SIGNAL
Compatible with Load Cells with greater than 0.25 mv/v
CONNECTORS
AMP plastic weather resistant circular connector. Gold plated contacts.
POWER REQUIREMENTS
10.5 to 16.0 V.D.C. 160 mA nominal with four 350Ω L.C.
SET UP AND CALIBRATION
Via front panel or saved when downloading the setting files.
GROSS RANGE
999,999 max-display
LOW BATTERY WARNING
Enabled at 10.5V nominal
POUND/KILOGRAM
Selectable
DISPLAY
6 Digit Chip On Glass LCD 1.7” high
DISPLAY RESOLUTION
.01, .02, .05, .1, .2, .5, 1, 2, 5, 10, 20, 50, 100
DISPLAY UPDATE RATE
Selectable: 1, 2, 3, 4 times/sec.
MAX. DISPLAY
RESOLUTION
Adjustable to 40,000 counts max.
ZERO TRACKING
Selectable, On/Off
SPAN ACCURACY
±(.1% + .005%/ °F) or (.1% + 0.009% °C) full scale ± 1 output count
MOTION DETECTION
Selectable, On/Off
ZERO ACCURACY
(.005%/ °F) or (0.009% °C) full scale ±1 output count for 0.5 mv/v transducer
ENVIRONMENTAL
ENCLOSURE
IP65, IEC 529
WEIGH ALGORITHM
3 internally selectable digital filters to optimize performance (General, Slow, and
Fast)
HOLD MODE
Used in mobile applications to stabilize displayed weight while moving the scale
NON-VOLATILE MEMORY
Standard
OPERATING TEMP
-29°C to 60°C -20°F to 140°F
2 REMOTE INPUTS
(Power/Remote ports)
Tare /Print / Hold / Net Gross / M+ / Zero / TR Hold / Re-enter Preset / Switch/
INGRED
Technical Specifications