background image

3D-MC² Setup and Calibration

3D-MC² Installation and Calibration Manual

4-14

Figure 4-18. Match Mast Angle and Mainfall Slope Angle

5. Press 

Mainfall slope

 

Set

 on the 

Adjust Slope

 screen, and enter the 

measured slope value. Press 

Set

 again to save the value.

Figure 4-19. Set Mainfall Slope

6. Place the machine on a different main slope to verify that the 

value is correct.

90°

Angle of Mainfall Slope = 2%

Angle of Mast =  2%

Adjust Mast Angle

to Match Angle of

Mainfall Slope

Содержание 3D-MC2

Страница 1: ...NSTALLATION AND ALIBRATION ANUAL...

Страница 2: ......

Страница 3: ...ight Topcon Positioning Systems Inc January 2009 All contents in this manual are copyrighted by Topcon All rights reserved The information contained herein may not be used accessed copied stored displ...

Страница 4: ...he information and data in this Manual are a valuable asset of TPS and are developed by the expenditure of considerable work time and money and are the result of original selection coordination and ar...

Страница 5: ...1 Preferred Method 2 1 Alternate Method 2 3 MC Sensor Cable Connections 3 1 3D MC Setup and Calibration 4 1 Entering 3D MC Parameters 4 1 MC Sensor Calibration 4 10 Calibrating Blade Slope 4 10 Calibr...

Страница 6: ...Table of Contents 3D MC Installation and Calibration Manual Notes ii...

Страница 7: ...dozer to run and operate at high speed while maintaining smooth grade using an MC sensor in place of the standard slope sensor Figure 1 1 3D MC Components on a Dozer 3 Radio Antenna Auto Manual Knob G...

Страница 8: ...Introduction 3D MC Installation and Calibration Manual Notes 1 2...

Страница 9: ...onto the dozer s blade 1 Weld the bracket onto the blade near the center of rotation See Figure 2 1 Figure 2 1 MC Location on Blade NOTICE Install the MC sensor near the center of the blade and not to...

Страница 10: ...2 2 2 Use all three socket head screws 2060 1058 and washers 2060 0180 to install the MC Sensor onto the bracket See Figure 2 2 Figure 2 2 MC Bracket Installation Preferred 2060 0158 Socket Head Scre...

Страница 11: ...or and existing weld 1 Using the adapter plate 9625 1001 as a guide drill a third mounting hole in the existing slope sensor bracket See Figure 2 3 on page 2 4 2 Install the adapter plate onto the slo...

Страница 12: ...l 2 4 Figure 2 3 MC Bracket Installation Alternate 2060 0158 Socket Head Screw 3 Plcs 2060 0180 Washer 3 Plcs MC Sensor Existing Slope Sensor Bracket Drill Third Hole Existing Holes 9625 1001 MC Senso...

Страница 13: ...LOWER RAISE RIGHT 2 GX 60 OPTIONAL RELAY FOR BACK UP ALARM VALVE CABLE 40 PIN CONNECTOR A 40 PIN CONNECTOR B BREAKOUT A CABLE HARNESS BREAKOUT B CABLE HARNESS TO UPPER CONNECTOR AUTO MANUAL SWITCH GX...

Страница 14: ...AUX GPS Antenna 9063 1156 Breakout A Adapter Harness 40 Pin Connector A 40 Pin Connector B LPS Antenna Radio Antenna MC R3 Controller 9063 1158 Breakout B Adapter Harness 5 Pin bayonet connector used...

Страница 15: ...cribed in this chapter from the MC sensor using a plum bob and tape measure Measurement accuracy must be within 1 2 for ideal performance All MC IMU measurements are referenced to the point of the arr...

Страница 16: ...3D MC Setup and Calibration 3D MC Installation and Calibration Manual 4 2 1 In 3DMC press Topcon Logo Control Machine setup Figure 4 2 Control Menu 2 Press New Figure 4 3 Machine files Screen...

Страница 17: ...eters 3D MC Installation and Calibration Manual 4 3 3 Enter the machine information and press Next Figure 4 4 Configuration name type Screen 4 Select 3DMC as the sensor type and press Next Figure 4 5...

Страница 18: ...om the center of blade rotation to the right side of the blade COR Center of Rotation For 6 way blades the COR is centered horizontally 1 2 blade width The COR is not usually centered vertically on th...

Страница 19: ...as the antenna type and enter the antenna measurement information 1 Above Vertical slant height measurement from the cutting edge to the antenna Figure 4 7 on page 4 6 2 Inside Horizontal distance fro...

Страница 20: ...3D MC Setup and Calibration 3D MC Installation and Calibration Manual 4 6 Figure 4 7 Antenna Measurements DISTANCE BEHIND CUTTING EDGE HE IGH T HE IGH T SLA NT HE IGH T ME AS UR EM EN T...

Страница 21: ...Entering 3D MC Parameters 3D MC Installation and Calibration Manual 4 7 Figure 4 8 Antenna Type and Measurements...

Страница 22: ...Press Next Figure 4 9 GPS Precisions Screen 6 Select UDP IP as the Connection type from the drop down menu in the GPS Comms Configuration screen as shown in Figure 4 10 on page 4 8 Your MC R3 controll...

Страница 23: ...Comms Configuration Screen 7 Set radio information and press Next Figure 4 11 Refer to the serial number radio label on the MC R3 controller to determine the correct radio type The radio type selectio...

Страница 24: ...using light bars select and enter LD 40 information and press Next Figure 4 12 If no light bars are in use press Next to bypass LD 40 setup Figure 4 12 LD 40 Setup Screen 9 Press Finish to save the m...

Страница 25: ...ibrating Blade Slope 1 Raise the blade a few inches and tilt the blade to one direction making it obvious which way the blade is tilted 2 Place a level on the cutting edge and measure the blade slope...

Страница 26: ...Blade slope Set on the Adjust Slope screen and enter the measured slope value Press Set again to save the value Figure 4 15 Set Blade Slope 4 Rotate the blade in the opposite direction and verify that...

Страница 27: ...e blade are on the same surface 2 Make sure the blade is flat on the ground and square to the machine 3 Measure the mainfall slope of the pad with the level Figure 4 17 Figure 4 17 Measure Main Slope...

Страница 28: ...Press Mainfall slope Set on the Adjust Slope screen and enter the measured slope value Press Set again to save the value Figure 4 19 Set Mainfall Slope 6 Place the machine on a different main slope t...

Страница 29: ...llation and Calibration Manual 4 15 Setting Valve Offsets In general set the offsets so that the valve just begins to move Do not set artificially large values as is sometimes typical in standard syst...

Страница 30: ...16 Setting Elevation Gain Gain settings vary by machine type though in general the raise gain value is higher than the lower gain value Figure 4 21 Set Elevation Gains Figure 4 22 Set Slope Gain NOTIC...

Страница 31: ......

Страница 32: ...National Drive Livermore CA 94550 800 443 4567 www topconpositioning com ISO 9001 2000 FM 68448 3D MC Installation and Callibration Manual P N 7010 0924 Rev A 01 09 2009 Topcon Corporation All rights...

Отзывы: