background image

Zeus200 

                                                           User Manual 

V 1.0.8 

– 12/10/2020 

          Page 2 of 16 

SUMMARY 

 

1.

 

Introduction ......................................................................................................................... 2

 

1.1

 

Usage rules ..................................................................................................................... 2

 

1.2

 

Basic operating principles and general indications .......................................................... 3

 

1.3

 

Fuel quality ...................................................................................................................... 4

 

2

 

System control .................................................................................................................... 5

 

2.1

 

Main Menu - Home .......................................................................................................... 6

 

2.1.1

 

Solar panel management .......................................................................................... 7

 

2.1.2

 

Thermoelectric generator management .................................................................... 7

 

2.1.3

 

Service battery .......................................................................................................... 8

 

2.1.4

 

Engine battery ........................................................................................................... 8

 

2.2

 

Settings Menu ................................................................................................................. 9

 

2.2.1

 

Timer Menu ............................................................................................................... 9

 

2.2.2

 

Mode Menu ............................................................................................................. 10

 

2.2.3

 

Language Menu ...................................................................................................... 11

 

2.2.4

 

Service Menu .......................................................................................................... 11

 

2.2.5

 

Update Menu .......................................................................................................... 12

 

2.2.6

 

Generator Menu ...................................................................................................... 12

 

2.2.7

 

Reset Function ........................................................................................................ 12

 

3

 

System messages and fault table .................................................................................... 13

 

4

 

Technical data ................................................................................................................... 15

 

5

 

Warranty ............................................................................................................................. 15

 

6

 

Possible checks ................................................................................................................ 16

 

7

 

Manufacturer ...................................................................................................................... 16

 

 
 

1. Introduction 

 

Thank you for purchasing a Mobil Tech product. With the Zeus200 thermoelectric generator you 
have  a  system  capable  of  charging  the  batteries  of  your  boat,  regardless  of  the  availability  of 
external electricity or weather conditions.  

 

Installation  and  commissioning  must  be  performed  by  specialized  personnel  only,  using  a 
dedicated  Installation  Manual.  This  User  Manual  describes  all  the  steps  to  be  taken  only  for 
normal system operation.

 

 

1.1  Usage rules 

Zeus200 can be installed on  boats  with a battery of  at  least 100Ah and 

it’s able to charge the 

boat batteries in a silent and ecological way, using only the fuel present in the tank. For gasoline 
powered boats it is necessary to install an additional tank. 
 
Use other than intended is not allowed. 
 
During installation and normal operation, the following instructions must be observed: 

  Installation must be performed by qualified personnel only 

  Usage is allowed in open places only   

  Use only the prescribed fuel 

  It  is  not  allowed to make  any  change  to  the system,  deleting or  inserting  other  types  of 

components 

Содержание ZEUS200 BD

Страница 1: ...r USER MANUAL ZEUS200 BD Power Supply Diesel IMPORTANT You can obtain the 3 three year warranty extension by registering the product for free on support mobiltech it More information can be found in c...

Страница 2: ...ble of charging the batteries of your boat regardless of the availability of external electricity or weather conditions Installation and commissioning must be performed by specialized personnel only u...

Страница 3: ...rking The operation is very harmful because the cooling of the device will be lost causing possible breakages due to overheating Any incorrect operation is recorded in the device memory General notes...

Страница 4: ...ash the generator using a pressure washer The generator is not designed to work submerged in water or other liquids in the event of flooding the warranty becomes void and it is necessary to go to an a...

Страница 5: ...the menu structure is shown HOME SETTINGS TIMER MODE LANGUAGE SERVICE GENERATOR CONTROL UNIT Timer 1 Timer 2 Clock Automatic Manual Battery automatic selection Engine battery forcing Italian English...

Страница 6: ...Manual mode generator not active The solar panel icon will be on only if the solar panel is charging The blue arrows with a continuous line indicate which of the energy sources is in operation and wh...

Страница 7: ...ntly both graphically and numerically 2 1 2 Thermoelectric generator management Pressing the generator icon the screen display the Menu related to the energy supplied by the thermoelectric generator T...

Страница 8: ...e to charge 12V and 24V secondary batteries The battery data is displayed on the left Type Actual voltage The percentage of engine battery charge is displayed on the right side of the screen Battery d...

Страница 9: ...wo available Timers as well as the internal clock To set a timer press the related time and make the desired adjustments in the central part of the screen When the two timers are activated the related...

Страница 10: ...the primary battery services with respect to the secondary one engine Nevertheless the latter is constantly monitored and if its voltage falls below a minimum value it will be immediately charged Bat...

Страница 11: ...ers Software update The two icons at the bottom right display the status of communications between the different components of the system C communication between the display unit and the power unit G...

Страница 12: ...ve on three different colors Gray working element actually not active Blue working element actually active Red failed element error issued In case of error it can be reset by pressing the relative ico...

Страница 13: ...service battery in a more ventilated place Display shows Engine batt low Low voltage of engine battery Turn on the generator and force the charge on the engine battery Switch on vehicle s engine if p...

Страница 14: ...let probe error Fault or lack of connection with outlet water probe Contact an authorized center for verification Display shows Water inlet probe error Fault or lack of connection with inlet water pro...

Страница 15: ...sidering the fact that the generator produces energy based on the thermal delta the production of energy varies according to the sea temperature In addition the system can be affected by other factors...

Страница 16: ...ch it Mail info mobiltech it service mobiltech it Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of operation Stamp and Signature Date Hours of oper...

Отзывы: